Scientech S310 Vector User Manual

Page 19

Advertising
background image

19

3. To Zero the Analog Needle (does not apply to the S310D):

Refer to Figure 3. The black slotted button located just below the display allows screwdriver adjustment to set
the analog needle to zero. This adjustment should be made before connecting a pyroelectric detector.

4. To Connect a Pyroelectric Detector:

Note: Only one detector should be plugged in at any time.

Refer to the drawing of the S310 rear panel in Figure 2. A 3 meter BNC type cable comes with Vector
pyroelectric detectors and Vector HR pyroelectric detectors. One of the input connectors on the rear panel of
the S310 is labeled "Vector" for hook up of the pyroelectric detectors.

5. To Select a Group:

A. Press the SETUP button. The Group Setting last used will appear in the display.


B. To move to the next Group, press SETUP button again.


C. To select the appropriate Group, press the SELECT button when the Group you desire appears in the

display (failure to press the SELECT button within 3 seconds will activate the Group shown in the
display and return the S310 to its operational state).

6. To Select a Range:

Note: AUTO range may be selected if the energy levels of repetitive pulses are to be measured.

However, do not select AUTO range if you want to measure single pulse energy or pulses
running at repetition rates lower than 10 Hz.

A. Press the RANGE button. On the first press of the RANGE button, the analog scale (if active) will

disappear. Then briefly press the RANGE button each time another range is desired.


B. To select a range, press the SELECT button when the range you desire appears in the display (failure to

press the SELECT button within 3 seconds will activate the range shown in the display and return the
S310 to its operational state). The ranges available for pyroelectric detectors are in the following table.

Model

Standard or SP

PHF02 - L

PHF02 – S or I

PHF05 – L

PHF05 – S or I

Mode Power Energy Power Energy Power Energy Power Energy Power Energy


Ranges

3mW

30mW

300mW

3W

AUTO

3mJ

30mJ

300mJ

3J

AUTO

30.00µW
3.000µW

3.000mW
30.00mW

AUTO

30.00µJ
3.000µJ

3.000mJ
30.00mJ

AUTO

3.000µW
30.00µW
300.0µW

3.000mW
30.00mW

AUTO

3.000µJ
30.00µJ
300.0µJ

3.000mJ
30.00mJ

AUTO

300.0µW

3.000mW
30.00mW

AUTO

300.0µJ

3.000mJ
30.00mJ

AUTO

3.000µW
30.00µW
300.0µW

3.000mW
30.00mW

AUTO

3.000µJ
30.00µJ
300.0µJ

3.000mJ
30.00mJ

AUTO

Model

PHF09 – L

PHF09 – S or I

P05

P09

Mode Power Energy Power Energy Power Energy Power Energy


Ranges

3.000mW
30.00mW

AUTO

3.000mJ
30.00mJ

AUTO

30.00µW
300.0µW

3.000mW
30.00mW

AUTO

30.00µJ
300.0µJ

3.000mJ
30.00mJ

AUTO

3.000µW
30.00µW
300.0µW

3.000mW
30.00mW

AUTO

3.000µJ
30.00µJ
300.0µJ

3.000mJ
30.00mJ

AUTO

3.000µW
30.00µW
300.0µW

3.000mW
30.00mW

AUTO

3.000µJ
30.00µJ
300.0µJ

3.000mJ
30.00mJ

AUTO