SkyHunter406 4000-10 AP User Manual

Page 11

Advertising
background image

11

4.2-3

AUTOMATIC FIXED (AF) (unit installed WITH the remote switch)

The Remote Switch functions as follows: (With Master Switch in "AUTO" position)

ON:

Used to remotely activate the transmitter for a test or emergency situation. An

example of such an emergency situation would be a forced landing with an impact
insufficient to activate the "G" switch.

AUTO: Used to arm the POINTER SENTRY ELT for automatic activation by the "G" switch

only.

RESET: Used to deactivate and rearm the transmitter after automatic activation by the "G"

switch.

.

4.3

FUNCTIONAL TEST OF AIRCRAFT-INSTALLED POINTER SENTRY ELT

4.4

MAINTENANCE

4.4-1

If the ELT fails to operate properly during the functional test, remove only the main unit and return to POINTER
AVIONICS for inspection and repair.

4.4

PERFORMANCE TEST (Canadian Registered Aircraft Requirement)

4.4.1

The Engineering and Inspection Manual, Part 1, Chapter III, Section 3.12.7(e) describes a performance test to be
accomplished every 12 months. This test MUST be carried out by an approved Avionics Facility and so certified
on a MAINTENANCE RELEASE TAG.