10

I N S T R U C T I O N M A N U A L • M O D E L S 1 0 9 9 / 1 0 9 6

CONNECTIONS

When making the initial connections, make sure all power is disconnected.

1. Connect the air supply source to the press air filter located at the right, rear

of the press head, using a hose having a minimum inside diameter of 1/8

inch (3 mm).

2. Connect the RF and base (actuating) cables of the press to the power

supply. (Consult your power supply instruction manual for details.)

3. Check with your electrician if you have any wiring questions.

OPTIONS

A Linear Encoder is available as an option. The Linear Encoder allows

distance-controlled welding in incremental and absolute modes.

The Linear Encoder is supplied with a 9-pin male connector that connects to

a matching 9-pin female connector on the power supply (factory installed).

NOTE: Do not strain or

kink the cables. When

going around corners,

allow as wide a bend as

possible. Do not run the

cables parallel to any

power line within a distance

of less than 1 foot

(304.8mm).

LINEAR ENCODER