Sonics 1096 Actuator User Manual

Page 17

Advertising
background image

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

16

I N S T R U C T I O N M A N U A L • M O D E L S 1 0 9 9 / 1 0 9 6

O P E R A T I O N

ACTUATION

The 1099 press is equipped with two maintained anti-repeat (non-tie-down)

palm buttons, one located on the left and one on the right side of the base of

the press. Both palm buttons must be pressed simultaneously to activate the

press to cycle the welder. To operate the press, follow these simple steps:

1. Depress both black palm buttons simultaneously.

2. Once the horn comes in contact with the part and the ultrasonics are

activated, release the palm buttons. If you release the buttons before

contact is made, the head will immediately return to its “home” position.

The operation of the 1096 actuator is controlled by the automated system. A

four-wire actuation cable is provided which ties into the output side of a PLC,

or other system controlling device. Momentary two wire closure from a dry

source will initiate the welder’s cycle. For more information, refer to the power

supply manual and the included wiring diagrams.

EMERGENCY STOP

To abort the 1099 press during welding, simply press the red EMERGENCY

STOP button located at the front center of the press base.

Once the EMERGENCY STOP button has been depressed, the head will

retract and return to its “home” position. Simply rotate the EMERGENCY

STOP button to the right 1/4 turn to release the press for further operation.

For the 1096 actuator, a four-wire actuation cable contains two normally

closed wires which control the emergency stop function. For more

information, refer to the power supply manual and the included wiring

diagrams.

NOTE: Power supply

cannot be shut off once the

weld cycle has started.

Termination of cycle can

only be achieved by using

the EMERGENCY STOP

button.

The equipment has safety

devices that require both

hands to be on the palm

buttons until the horn

contacts the workpiece. Do

not defeat or modify

these safety devices.

Do not use with a

footswitch unless alternate

means of pinch-point

protection is provided.

Advertising