REQUIREMENTS/SPECIFICATIONS

2-3

Maximum Lobe Lengths

Lobe length is the physical length of the cable connecting a station to its
TCU port at the MicroMMAC-T. Table 2-2 lists the maximum lobe cable
length for ring speeds of 4 and 16 Mbps. The values listed refer to total
lengths made up of UTP cable only.

Type 3 Media Filters

A Type 3 Media Filter is required when connecting a UTP lobe segment
from a MicroMMAC-22T or MicroMMAC-24T to a station supporting
STP cabling. Cabletron Systems offers the following Type 3 Media Filters:

TRMF, RJ45 (UTP) connector to 10-inch DB9 (STP) cable with
LANVIEW

TRMF-2, RJ45 (UTP) connector to DB9 (STP) connector

Maximum Number of Stations

When UTP lobe cabling is used in any ring segment, the number of ring
stations supported by the MicroMMAC-T is limited to 150, regardless of
the operating ring speed.

Table 2-2. UTP Maximum Lobe Lengths

UTP Cable Type

Maximum Lobe Length

4 Mbps

16 Mbps

Category 3

200 meters

100 meters

(656 feet)

(328 feet)

Category 4

200 meters

100 meters

(656 feet)

(328 feet)

Category 5

250 meters

120 meters

(820 feet)

(394 feet)