3 installing the micrommac-t, 1 rack-mounting the micrommac-t, 3 installing the micrommac-t – Cabletron Systems MicroMMAC 24T MICROMMAC- User Manual

Page 37: 1 rack-mounting the micrommac-t

Advertising
background image

INSTALLATION

3-2

Figure 3-1. Attaching the Strain Relief Bracket

3.3 INSTALLING THE MicroMMAC-T

The MicroMMAC-T can be rack-mounted, wall-mounted, or placed on
any horizontal surface. Refer to the following subsections for the
appropriate installation instructions. When installing the MicroMMAC-T
into something other than a 19-inch rack, installation requires the
following:

An unrestricted free surface area at least 21 inches wide, 18 inches
deep, and 6 inches high.

A single phase 85 to 264 Vac, 15A, grounded power receptacle located
within 7 feet of the site.

If a shelving unit is used, it must be able to support 30 pounds of static
weight.

The temperature in selected location must be between 5

°

and 50

°

C,

and change less than 10

°

C per hour.

NOTE: Be sure that the selected location is within reach of the network
cabling.

3.3.1 Rack-Mounting the MicroMMAC-T

Refer to Figure 3-2 and perform the following steps to install the
MicroMMAC-T in a 19-inch rack:

1. Remove the four cover screws located along the front edges of each

side of the MicroMMAC-T.

TOKEN RING HUB

WITH

LANVIEW®

SUPPORTING 100 OHM STP CABLE

MicroMMAC-24T