INSTALLATION

3-13

3.9.1 Setting Phantom and RI/RO Switches

The Phantom Switch (shown in Figure 3-13) enables the port to
“autowrap” if a trunk cable fails or is removed. The Phantom Switch
should be set to the appropriate setting before TPIM installation. When
attaching a Cabletron hub to the TPIM, leave the switch at the factory
default setting of 1. When attaching a non-Cabletron device to the TPIM,
such as an IBM 8228 MAU, use the 0 setting.

Ensure that the Ring-In/Ring-Out Switch is in the factory default RI/RO
position. The MicroMMAC-T does not support the Station (S) setting.

NOTE: If the switch locations on the TPIM do not match the locations
illustrated in Figure 3-13, r
efer to the TPIM Reference Card included with
the TPIM. The TPIM Reference Card outlines switch locations and
settings. For additional help, call Cabletron Systems Technical Support.

RX+

4

6

1

9

RX-

5

3

6

5

Table 3-1. Pinout Cross-Reference for TPIMs (Cont.)

Signal

TPIM-T2/T4

(RJ45)

Ring-In

TPIM-T2/T4

(RJ45)

Ring-Out

TPIM-T1

(DB9)

Ring-In

TPIM-T1

(DB9)

Ring-Out