5 connecting fiber optic link segments, 5 connecting fiber optic link segments – Cabletron Systems MicroMMAC 24T MICROMMAC- User Manual

Page 52

Advertising
background image

INSTALLATION

3-17

Figure 3-16. The TPIM-T2/-T4

2. Check that the LNK LED on the TPIM lights green. If the LED lights

red or is not lit, perform each of the following steps:

a.

Check that the device at the other end of the segment has power.

b.

Verify that the RJ45 is pinned properly.

c.

Check that the twisted pair connection meets dB loss limits and
cable specifications outlined in Chapter 2.

d. Check that the port is enabled through Local Management.

e.

If a link still can not be established, contact Cabletron Systems
Technical Support.

3.9.5 Connecting Fiber Optic Link Segments

Use TPIMs -F2/ -F3 to connect Fiber Optic Link segments. When
connecting a fiber optic link segment to the TPIM-F2 or TPIM-F3 consider
the following:

Fiber optic link segments with ST connectors attach to ST ports much
like BNC connectors attach to BNC ports. The connector is inserted
into the port with the alignment key on the connector inserted into the
alignment slot on the port. The connector is then turned to lock it
down.

RI

RO

6

5

4

3

2

1

18

17

16

15

14

13

TPIM-T2

LNK

TPIM-T2

LNK

Advertising
This manual is related to the following products: