BEFORE proceeding with these instructions

verify the type of log set you have. Is it a DUAL

BURNER Set (Models MO18NG, MO24NG,

SH18NG, SH24NG, CSO30NG) OR an

INFRARED Set (Models GO18TIR or GO24TIR)?
1. If a DUAL BURNER Set proceed with the

instructions beginning below through

page 3.
2. If an INFRARED Set proceed with

instructions starting on page 4 continuing

through page 5.

SINGLE, DUAL & TOPSIDE SYSTEMS

(For Infrared Systems See Page 3)

INSTALLATION OF NATURAL GAS PILOT VALVE

This Safety Pilot Kit contains a Control Valve certified by C.S.A., which provides a safe and convenient way to

ignite your energy efficient gas log set.
Note: Use pipe compound on all male threads to seal joints.

A. This Safety Pilot Kit contains a Natural Gas Orifice and L.P. Gas

hardware. Instructions are packaged separately in this kit.

B. Attach the 3/8” Natural Gas Orifice (Part #20a or #20b) through the

Burner Pan to the Burner Bar using the 3/8” Locknut supplied only

with Dual and Topside Burner log sets. When installing a single burner

log set, a 3/8” locknut is not used. Be sure the small drill hole on the

3/8” Natural Gas Orifice is facing the gas control valve and the large

hole is facing the burner pan. (See Figure 1 & 2)

C. Connect a 3/8” female elbow (Part #19) to the Natural Gas Orifice.

(See Figure 3)

D. Connect the 3” Pipe Nipple (Part #18) to elbow. (See Figure 4)
E. Connect the second 3/8” female elbow (Part # 19) to the 3” Pipe Nipple.

(See Figure 5)

STOP

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Advertising