Installation of natural gas pilot valve (cont.) – Sure Heat CVS303 Natural Gas Conversion Kit User Manual

Page 3

Advertising
background image

INSTALLATION OF NATURAL GAS PILOT VALVE (cont.)

F. Connect the 90 degree street elbow (Part #17) to the 3/8” female elbow.

(See Figure 6)

G. Slide the hole in the heat shield (Part #15) over the 3/8” NPT threads on

the Gas Control Valve (Part # 3). (See Figure 7)

H. Then secure the heat shield in place with the lock nut (Part # 16).

(See Figure 8)

I. Attach the control valve & heat shield assembly to the 90 degree street

Elbow. (See Figures 9 & 10)

J. Attach the pilot bracket (Part # 8) to the burner pan using the sheet

metal screw (Part # 9). (See Figure 11)

NOTE: The Pilot Bracket utilizes four mounting holes for adjustment

of the Pilot Burner Assembly should your installation require repositioning.

Repositioning of the Pilot Burner Assembly may be necessary if the log

set is experiencing intermittent shutdown. Shutdown is caused by

overheating of the Pilot Burner Assembly by the main burner flame.

If shut down is occurring, move the Pilot Burner Assembly over to the

next mounting hole so that only the tips of the Pilot Burner Assembly

are hanging over the Burner Pan.

K. Carefully bend the Thermocouple lead (Part #5) and attach to the

back of the control valve. (See Figure 12)

NOTE: When screwing into the Control Valve, hand tighten both the

Pilot Gas supply line and Thermocouple Lead, then tighten 1/8 turn

with a wrench. DO NOT OVER TIGHTEN as this will cause the Pilot

to not function properly.

L. Attach pilot gas supply line (Part # 6) to the bottom of the gas control

valve. Care should be taken not to kink the tubing which would restrict

gas flow to the Pilot Burner. (See Figure 13)

Figure 6

Figure 7

Figure 8

Figure 9

Figure 10

Figure 12

Figure 13

Figure 11

Advertising