SUUNTO Zoop User Manual

Page 55

Advertising
background image

53

Three single beeps with a two second interval occurs, when:

• the no-decompression dive turns into a decompression stop dive. An arrow point-

ing upwards and the blinking ascent warning ASC TIME will appear (Fig. 3.15.).

Continuous beeps for 5 seconds occur, when:

• the maximum allowed ascent rate, 10 m/min [33 ft/min], is exceeded. SLOW and

STOP warnings will appear (Fig. 3.12.).

• the Mandatory Safety Stop ceiling is exceeded. A downward pointing arrow will

appear (Fig. 3.14.).

• the decompression ceiling depth is exceeded. An error warning Er and a down-

ward pointing arrow appear. You should immediately descend to, or below, the

ceiling. The instrument will otherwise enter a permanent Error Mode within three

minutes, indicated by a permanent Er (Fig. 3.18.).

You are able to preset alarms before the actual dive. The user programmable alarms

can be set for maximum depth and dive time. The alarms activate when:

• The preset maximum depth is reached

• continuous beep series for 24 seconds or until any button is pressed.

• the maximum depth blinks as long as the present depth value exceeds the ad-

justed value.

• The preset dive time is reached

• continuous beep series for 24 seconds or until any button is pressed.

• the dive time blinks for one minute, if no button is pressed.