Fieldpilot, Install tank adapters and hose, Install ef adapters and hose – TeeJet FieldPilot Install Miller Condor User Manual

Page 14

Advertising
background image

12

www.teejet.com

FieldPilot

®

5. install tank adaPters and hose

Connect run tee adapter

(N)

to the hydraulic accessories pressure hose removed from the priority flow control

valve in Step 4. Connect hose

(J)

to the T port on the FieldPilot Valve. Route the other end of hose

(J)

to the run

of run tee

(N)

.

Figure 1-9: Install Tank Adapters and Hose

6. install eF adaPters and hose

Connect the hose

(K)

to the EF port of the FieldPilot Valve. Route the 90° end of hose

(K)

to the branch run tee

adapter

(N)

.

Figure 1-10: Install EF Adapters and Hose

n

J

J

n

J

K

K