Trouble shooting the gas control system, Honeywell millivolt valve – Vermont Casting IRHEDV32 User Manual

Page 14

Advertising
background image

14

10003929

• GAS SUPPLY ON

• SUPPLY LINE HOOKED UP
• SHUTOFF VALVE OPEN

NO

NO

NO

NO

• LOCKOUT HAS ENGAGED. WAIT
60 SECONDS AND TRY AGAIN.
• FOR SPARK AT ELECTRODE
WHILE DEPRESSING PIEZO
— 1/8" GAP TO
PILOT HOOD NEEDED.
• ALL WIRING CONNECTIONS
• REPLACE PIEZO IGNITOR

• FOR AIR IN THE LINES
• THERMOPILE NEEDS A
MINIMUM 325mV. ADJUST
PILOT FLAME HEIGHT.
• ALL WIRING CONNECTIONS.
• REPLACE THERMOPILE
• THERMOCOUPLE NEEDS A
MINIMUM OF 14mV.
• DEFECTIVE VALVE. TURN TO
PILOT, METER SHOULD READ
GREATER THAN 100 mV. IF
NOT, REPLACE.

PILOT LIGHTS WITH
PIEZO IGNITOR

YES

YES

YES

YES

PILOT STAYS LIT

PILOT LIGHTS MAIN
BURNER

SYSTEM OK.

START

CHECK

• VALVE IS TURNED ON
• ON/OFF SWITCH IS NOT
TURNED ON. WATCH
FOR GROUNDED WIRES!
• THERMOPILE NEEDS A
MINIMUM 325mV.
• PLUGGED BURNER ORIFICE.

TROUBLE SHOOTING THE GAS CONTROL SYSTEM

HONEYWELL MILLIVOLT VALVE