INSTALLATION OF TRIM SWITCH

FOR RP GAS VALVES

1.

Thread wire through openings on the right side of
fireplace. Do not cut wire or insulation on metal edges.

2.

Slide switch assembly from the back, between
subframe and trim, then fasten the screw. (Fig. 3)

3.

For left side installation reverse switch position in
bracket and repeat Step 2 (Fig. 4 ).

4.

Connect wiring to gas valve (Fig. 5a & b) and switch.

CAUTION: DO NOT WIRE MILLIVOLT
REMOTE WALL SWITCH FOR GAS
FIREPLACE TO A 120V POWER SUPPLY.

ADJUSTMENT OF LEVELLING BAR

(IF REQUIRED)

1. Determine height of adjustment.
2. Loosen the four (4) screws. (Fig. 6)
3. Set bar at proper height and tighten the screws.
4. Add the two (2) extra screws to prevent any movement.

VENTING AND INSTALLATION

1. The Irving Oil fireplace may be installed in and

vented through any solid fuel fireplace that has a
minimum fireplace opening 28-3/4" wide x 21-1/4"
high x 16" deep and has been installed in
accordance with the National, Provincial/State and
local building codes and is constructed of non-
combustible materials.

2. Only HEDVT (8 x 12) or HEDVT (12 x 12)

termination kit and flex vent kit HEDVK25 or
HEDVK35 is able to be used in this installation.
Under no circumstances should B vent or C vent
be used on this application.

3. Any flue damper must be removed or blocked open.
4. The chimney must be clean and in good working

order and constructed of non-combustible materials.

5. Make sure that all chimney cleanouts fit properly so

air cannot leak into the chimney.

6. Install the appliance without trim frame and make all

gas fittings and electrical connections.

7. Install the decorative trim frame. Please refer to the

Frame Assembly instructions.

Fig. 6

Trim

Screw

Wiring from millivolt

gas valve

On/Off switch

assembly

Fig. 3

Bracket Switch

On/Off switch

Trim

Screw

Trim
Left
Side

Trim Top

On/Off Switch

Assembly

Wiring from millivolt

gas valve

Fig. 4

Fig. 5a

Fig. 5b

-----

-----

LEVELLING BAR

SET SCREWS

BACK OF UNIT

PILO

T

TPTH

TP

TH

SIT VALVE

THERMOPILE

ON/OFF SWITCH OR

MILLVOLT THERMOSTAT

PILOT

ADJ

TH

TP

TP TH

HONEYWELL VALVE