Sx-2000ao and sx-2100ao – Toa SX-2000 Series Installation User Manual

Page 124

Advertising
background image

124

4.4.3. SX-2000AO and SX-2100AO

[Connecting control input terminals to the TT-104B program timer]

Since the SX-2000Ao's or SX-2100Ao's control inputs are photo coupler inputs, they need a power supply.

Power can be supplied to the photo couplers using the SX-2000Ao's or SX-2100Ao's internal power supply, or

external power supply.

• When using the internal power supply, 2 power feed jumpers and 2 isolation jumpers are needed. Using 6P

removable terminal plugs equipped with jumpers, make connections as shown below:

TT-104B

OUTPUT CHANNEL (24 V DC 0.5 A)

BE SURE TO SET

THIS SWITCH TO “ON”

AFTER INSTALLATION

ON

MEMORY

BACK UP

CHANNEL

ASSIGNMENT

OFF

ON

OFF

CAUTION

SX-2100AO or SX-2000AO

(The figure below shows the SX-2100AO.)

OUTPUT CHANNEL (24 V DC 0.5 A)

Power Feed Jumper

Control input terminals

Power Feed Jumper

Isolation Jumper

Isolation Jumper

Open voltage: Under 40 V DC

Short-circuit current: 2 mA

Cable: AWG22 – 28

twisted pair cable

6P removable terminal plugs

(supplied with the SX-2000AO

and SX-2100AO)

[Operation of power Feed Jumper and Isolation Jumper]

VCC

GND

-

+

Power feed jumper

Photo coupler

Internal circuit

Isolation jumper

Control input