2.5.3. CpU OFF function (general urgency all-call) settings

(RM-200SF: DIp switch 6 operation or RM-200SA: DIp switch 5 operation)

the cPu off function permits the all-zone calls to be made from the rm-200Sf or rm-200SA by bypassing

the cPu*

1

normally used by the SX-2000 system and using an analog link instead. this function is usually used

if a system failure is preventing normal broadcasts from being made. Announcement from the rm-200Sf can

be made to all zones within the system only while the talk Switch is being pressed with the cPu switch on its

top panel set to off, or announcement from the rm-200SA can be made to the said zones while its General

urgency All-call key is being held down for 4 seconds or more. Whether or not this function is available can

be set using DIP switch 6 on the bottom panel of the rm-200Sf or DIP switch 5 on the side panel of the rm-

200SA. (regarding how to make such broadcasts, see the separate operating Instructions, "operation.")

If the SX-2000 system receives a 24 V emergency cutoff signal*

2

, the general urgency all-call using the cPu

off function is disabled because the emergency system other than the SX-2000 system takes precedence

over the SX-2000 system.

*

1

cPu is a central processing unit, which is built in the SX-2000Sm, SX-2000AI, SX-2100AI, SX-2000Ao, and

SX-2100Ao.

*

2

In the SX-2000 system, a 24 V emergency cutoff input terminal that allows control of an emergency audio

input is provided on the SX-2000Ao's rear panel. When the SX-2000 system is combined with another

emergency system, a 24 V Dc is normally kept being supplied to this 24 V emergency cutoff input terminal

and is cut off in emergency situations. this interrupts the general-purpose broadcast from the SX-2000,

allowing the emergency system other than the SX-2000 system to override it.

8

7

6

5

4

3

2

1

TERMINATION

CPU OFF

LEVEL METER

COMMUNICATION

UNIT ID

On

Off

DIP SWITCH

RM-200SF bottom

RM-200SA side

1

2

ON

3

4

5

6

7

8

1

2

3

4

5

6

Note

Set the cPu off function to "Disabled" as in the table below for systems that do not use the analog link.

Disabled

Enabled

OFF

ON

(Default position)

DIP Switch

CPU OFF Function

(General urgency

all-call)

RM-200SA

RM-200SF

1

2

3

4

5

6

1

2

3

4

5

6

1

2

ON

3

4

5

6

7

8

1

2

ON

3

4

5

6

7

8