Input ch2 Hpf 31.5Hz

A2H, 04H, 00H, 01H, 00H, 03H

A2H, 04H, 00H, 01H, 00H, 03H

Output ch1 Lpf 6.3kHz

A2H, 04H, 01H, 00H, 01H, 02H

A2H, 04H, 01H, 00H, 01H, 02H

Command Controller

9000M2

Response

Input sensitivity setting

Input ch1 Insense -24dB

ACH, 02H, 00H, 02H

ACH, 02H, 00H, 02H

Speaker preset setting

Output ch2 SpPreset F-122

ADH, 02H, 01H, 01H

ADH, 02H, 01H, 01H

Phantom power setting

Input ch3 Phantom ON

87H, 02H, 02H, 01H

87H, 02H, 02H, 01H

Paging Event Preset Recall

Paging No1 Activates

F2H,02H,00H,01

F2H,02H,00H,01

Channel name recall

Input ch1 Name “INPUT1”

F0H, 03H, 40H, 00H, 00H

C0H, 09H, 00H, 00H,
49H, 4EH, 50H,
55H, 54H, 31H, 00H

ANC ADJUST

Reference Level Of Ch1 to
–9dB

AEH,02H,00H,01H C1H,01H,00H

ANC Get Reference

Acquiring reference level of
Ch1

F3H,01H,00h C2H,01H,32H(0dB)