2. SERIAL PORT SETTING

9,600/19,200/38,400/57,600 bps, 8 bits, non-parity, stop bit: 1, non flow control

Connector: D-sub 9 pins, straight cable

Signal line: No.2=TX, No.3=RX, No.5=Ground

3. COMMAND CONFIGURATION


• is in the range of 80H to FFH. and are in the

range of 00H to 7FH.

• Data length (N) refers to the length of the subsequent data of Data 1 to Data N.
• If received data contains more byte data than the Data length, these exceeding data are

abandoned.

• If a next command received contains byte data shorter than the Data length, the previous

command is abandoned.

4. TRANSMISSION DATA AFTER COMMAND RECEPTION


When normal data is received, the same data as the reception data is to be transmitted.
Example: 91H, 03H, 00H, 00H, 00H (Reception data)

91H, 03H, 00H, 00H, 00H (Transmission data)


When channel data is received and the data is outside of the range, the data is to be
inverted and transmitted.
Example: 91H, 03H, 00H, 08H, 00H (Reception data)

91H, 03H, 00H, 77H, 00H (Transmission data)


When abnormal data is received, the data is to be inverted and transmitted.
Example: 91H, 03H, 00H, 00H, 6AH (Reception data)

91H, 03H, 00H, 00H, 15H (Transmission data)


When data other than channel data is received and the data is outside of the range, no data
is transmitted.
Example: 91H, 03H, 05H, 00H, 6AH (Reception data)

No response



See section 9.

COMMUNICATION EXAMPLES for other transmission data when normal

data is received.

Command

Data length

(N)

Data 1

Data 2

Data N

Data

Data

length

Command