Iii before installing – Crown Boiler KSZ175 User Manual

Page 5

Advertising
background image

3

taBlE 1a: GEnEral SPEcIFIcatIOnS

Notes:

1. Net Ratings are based on piping and pick-up allowances of 1.333.
2. Burner Capacity Rating, GPH is based on #2 oil with a Gross Heating

Value equal to 140000 BTU/Gal.
3. Maximum Working Pressure, Steam -15 PSI.
4. Tankless heater ratings based on 40F inlet water, 140F outlet water, and 190F

boiler water. Ratings are also based on 5 minute intermittent draws with 10 minutes

between draws.

III Before Installing

1) Safe, reliable operation of this boiler depends upon installation by a professional heating contractor in strict accordance

with this manual and the requirements of the authority having jurisdiction.

In the absence of an authority having jurisdiction, installation must be in accordance with this manual and the latest

edition of Installation of Oil Burning Equipment (ANSI/NFPA31).

Where required by the authority having jurisdiction, this installation must conform to the latest edition of Standard for

Controls and Safety Devices for Automatically Fired Boilers (ANSI/ASME CSD-1).

2) Make sure that a properly sized chimney is available which is in good condition. Consult the authority having

jurisdiction, Part VI of this manual, and

ANSI/NFPA31 for additional information on venting requirements.

Power (“Side Wall”) Venting - Important note

Two problems arise when any oil-fired appliance is power vented:

1. There is sometimes an accelerated rate of soot buildup on the oil burner cad-cell, spinner etc.
2. There is a potential for severe damage to the side of the structure in the event that the boiler operates at a high smoke

level. This can happen for many reasons, some of which are out of the control of both the installer and appliance

manufacturer.

Crown Boiler Company recommends the use of a chimney to vent the KSZ series boilers. If a power venter must be used, it

is the responsibility of the installer and power vent manufacturer to “engineer” the power vent system. crOWn BOIlEr

cOMPanY WIll aSSuME nO rESPOnSIBIlItY FOr DaMaGE tO SIDInG, Etc. FrOM a POWEr

taBlE 1b: tanKlESS HEatEr ratInGS

"A"

"B"

"C"

KSZ065

3

0.65

79000

85.1

59000

246

17-3/8

8-5/16

6

KSZ075

3

0.75

90000

84.5

68000

283

17-3/8

8-5/16

6

KSZ100

3

1.00

119000

83.5

89000

370

17-3/8

8-5/16

6

KSZ090

4

0.90

110000

85.0

83000

346

22-3/8

10-13/16

7

KSZ125

4

1.25

149000

84.2

112000

467

22-3/8

10-13/16

7

KSZ150

4

1.50

177000

83.1

133000

554

22-3/8

10-13/16

7

KSZ120

5

1.20

147000

85.4

110000

458

27-3/8

13-5/16

8

KSZ175

5

1.75

207000

83.1

155000

646

27-3/8

13-5/16

8

KSZ200

5

2.00

235000

82.9

176000

733

27-3/8

13-5/16

8

I=B=R Net

Rating (Sq. ft)

AFUE (%)

I=B=R Net

Rating (Btu/hr)

Dimensions (inches)

Boiler Model

Number of

Sections

Burner

Input

(Gal/hr)

DOE Heating

Capacity

(Btu/hr)

MODEL

RATING (gpm)

KSZ065

2.25

KSZ075

2.25

KSZ100

2.50

KSZ090

2.50

KSZ125

2.75

KSZ150

3.00

KSZ120

2.75

KSZ175

3.25

KSZ200

3.50