Sealing points

4. Secure the cable bushing to the Wall Mounting Bracket, then waterproof 2 points shown in the figure below

with silicone sealant material.

5. Replace the connectors removed in Step 1 on the end of the composite cable.

Note: Pay attention to the correct cable connections. Incorrect wiring at the connectors may cause damage

to the connected equipment.

Input connector

Power supply connector

1

VIDEO

2

GND

3

RS485 +

4

RS485 -

5

GND

6

AL1

7

AL2

8

AL3

9

AL4

Power supply connector

Terminal No. Terminal name

Cable color

Terminal
treatment

1

24V AC

Red

AC adapter jack

2

24V AC

Black

Input/Output connector

Terminal No. Terminal name

Cable color

Terminal

treatment

Yellow

Shield

BNC jack

Green

Bare end

Blue

White

Brown

Purple

Orange

Gray

Bare end

Bare end

Bare end

Bare end

Bare end

Bare end