Toa C-PH200 User Manual

Page 10

Advertising
background image

10

Terminal

Video connection terminal

Bushing plate

Coaxial cable

Control input cable

Bushing for coaxial cable
Applicable cable diameter: 4 – 8 mm

Bushing for control input cable
Applicable cable diameter: 13 – 18 mm

3. Connect lead wires to the terminal.

Note
Take care not to confuse the upper terminal with the lower terminal when making terminal connections.

5.5. Coaxial Cable End Processing

Process the coaxial cable end as follows:

5.5.1. 3C-2V Cable

1. Strip the cable sheath 20 mm from the cable end.
2. Bend back braided copper shields over the cable sheath, then remove

the insulating material 15 mm from the cable end.

5.5.2. 5C-2V Cable

1. Strip the cable sheath 30 mm from the cable end, and braided copper

shields 20 mm.

2. Remove the insulating material 15 mm from the cable end.