5.9. Notes on Operations by Auto-Pan Control

When using an auto-pan function to operate the C-PH200 Pan/Tilt Head, be sure to make the following
changes to best meet particular requirements of connected control equipment. Failure to do so could cause
the pan/tilt head’s malfunctions.

5.9.1. If using the CC-5011B Direct Control System Remote Control unit…

Open the CC-5011B’s case and cut JP1 on the RC-1A circuit board with nippers. For details, please read the
section “Connections” of the instruction manual for the CC-5011B.

5.9.2. If using the CC-5120 Relay Box…

Open the CC-5120’s case and cut JP1 on the RB-1A circuit board with nippers.

5.9.3. If using the C-RB100 Coaxial Multiplex Control Relay Box…

Open the C-RB100’s case and perform settings for the SW3 Pan/Tilt Head Installation Setting switch. Set the
switch to “0,” “7,” “8,” or “9” when installing the C-PH200 unit upright, and to “1” when installing it in a
suspended (upside-down) position. (Factory-preset to “0.”)
For more information about this, refer to the section “Settings” of the instruction manual for the C-RB100.

RC-1A

JP1

C-PH200

CC-5941B

CC-5011B

Terminal block

RB-1A

JP1

C-PH200

CC-5120

CC-5111B

C-RB100

SW3

C-PH200

C-RB100

0

1

2

3

4

5

6

7 8 9

Coaxial Multiplex

Controler