6

Connecting The Digital Indicator To
The Weighing Platform

STANDARD TSM SERIES DIGITAL INDICATORS
The TSM Series Low Profile Scale is typically
purchased as a complete, factory calibrated
weighing system, which includes a compatible digital
indicator and all required cables and cords. The
digital indicator model will vary according to which
floor scale system was purchased. This section
covers connecting the TSM floor scale platform to
digital indicator models TS-700 MS, TS-700 SS and
7600e.

THE CONNECTING CABLE WILL BE FOUND IN

ONE OF TWO LOCATIONS, DEPENDING ON THE
MODEL OF INDICATOR PURCHASED. IT WILL BE IN
THE SHIPPING CARTON WITH THE INDICATOR, OR
BUNDLED INSIDE THE JUNCTION BOX AREA INSIDE
THE WEIGHING PLATFORM.

For all Models: Locate the junction box access
plate on the outside edge of the weighing platform
deck. Unscrew the two screws and remove the
plate.

Connect the indicator to the platform according to
the model, as follows:

CONNECTING A TS-700 MS INDICATOR
(The interface cable is pre-wired to the weighing
platform junction box and it quick-connects to
the digital indicator)

1. Feed the cable out of the junction box area

through the hole at the bottom of the cavity.

2. Connect the cable to the digital indicator.