I product description, Ii specifications – Crown Boiler BWF061 User Manual

Page 3

Advertising
background image

2

I Product Description


The BWF series boiler is a cast iron gas fired boiler designed for use in forced hot water heating systems. The BWF is
intended for installations where a usable chimney is not available. The BWF is normally vented using an approved vertical or
horizontal AL29-4C stainless steel venting system, which is not included with the boiler. If a suitable chimney is available, the
BWF series can be vented into it using an optional BWF Category I Vent Kit available from Crown. The BWF requires an
adequate source of clean combustion air in the boiler room.
The BWF boiler is not designed for use in gravity or “open” heating systems. Where an adequate source of clean indoor
combustion air cannot be guaranteed, use a direct vent boiler such as the Crown CSC series.

II Specifications




























BWF061EN

3

61,000

51,000

44,000

83.3

14 1/4

3.2

BWF095EN

4

95,000

78,000

68,000

83.1

17 1/2

4.0

BWF128EN

5

128,000

106,000

92,000

82.8

20 3/4

4.7

BWF162EN

6

162,000

134,000

117,000

82.5

24

5.5

BWF195EN

7

195,000

161,000

140,000

82.3

27 1/4

6.3

BWF229EN

8

229,000

189,000

164,000

82.0

30 1/2

7.0

4

* MODELS SHOWN ARE FOR NATURAL GAS. REPLACE "N" WITH "L" SUFFIX FOR PROPANE MODEL NUMBER (e.g. BWF061EL).
PERFORMANCE RATINGS ARE THE SAME FOR BOTH FUELS

3
3
3
4

WATER

CONTENT

(GAL.)

TABLE 1: SPECIFICATIONS

AFUE (%)

FIG. 1

DIMENSION

"A" (IN.)

D.O.E.

HEATING

CAPY.

(BTU/hr)

VENT DIA.

(IN.)

3

MODEL*

NO.

SECTIONS

INPUT

(BTU/hr)

IBR NET

RATING

(BTU/hr)

Advertising