SAFETY PRECAUTIONS

1. Check if an eiectric leakage occurs in the set.

2. When servicing current applying parts, unplug prior to

servicing.

3. In case of testing with power injecting, wear rubber

gloves to prevent electric shock.

4. If you use any appliances, check regular current, voltage

and capacity.

5. Don't touch metal products In cold freezer room with wet

hand. It may cause frostbite.

6. Prevent water flowing to electric elements in mechanical

parts.

7. When sloping the set, remove any materials on the set,

especially thin plate type(ex,: glass plates or books.).

8. When servicing evaporator part, wear cotton gloves

without fail. It is to prevent wound by sharp fin of

evaporator.

9. Leave a breakage freezing cycle to a heavy service

center. The gas in cycle inside may soil ambient air.

SERVICING PRECAUTIONS

AIR RECHARGING IN COMPRESSOR

Test the refrigeration system by connecting it electrically

before refilling operation. This is necessary to ascertain the

function of the motor-compressor and identify the defects

immediately. If the defects have been found, empty the old

system of eventual R-12 residue by breaking off the end of
the extension piece at its narrow point. (Figure 1)

Replace the filter and any damaged components. Unsolder

and pull off the piece remaining inside the service tube and
then attach an extension completely with male Hansen and

last, solder it to the same tube again. (Figure 2)

It is necessary to execute the soldering operation with

valve open so that the fumes caused by oil residue can
come out freely without blowholes between two tubes
during heating the point to be soldered.

The extension fitted with the male Hansen is connected to
the female fitting of the vacuum pump tube. (Figure 3)

Air evacuating from the system begins as soon as the

pump starts. The refrigeration system must be kept under

vacuum until the reading on the low-pressure gauge

indicates vacuum (0 absolute, -1 atm., -760 mm Hg) In any

case it is advisable to keep the pump running for about

30 minutes. (Figure 4)

POINT TO BE

BROKEN

SERVICE TUBE

EXTENSION

Figure 1

CHARGE TUBE FEMALE

EXTENSION HANSEN

POINT

Figure 2

Figure 3

Figure 4

-