TROUBLESHOOTING

ОКРЕСТ

effect

CAUSE

REMEDY

GROUP PARTIALLY
OR COMPLETELY
OUT OF
REFRIGERANT
CHARGE

Evaporator dose not frost even

though motor-compressor runs
continually.

An empty refrigerant system

indicates a leakage of R134a. This
loss is generally to be looked for at

the soldering points connecting the
various components or In an
eventual hole in the evaporator

made by the user.

Leakage must be eliminated by
resoldering the defective point or

substituting the damaged
evaporator.

EXCESSIVELY
FULL

This defect is Indicated by the

presence of water outside
refrigerator near the motor caused
by formations of ice on the return

tube.

If In the refrigerant system a quantity

of R134a is introduced which is
greater than that indicated, the
excess gas dose not terminate its
expansion in the evaporator but

proceeds into the return tube.

The system must be emptied and
subsequently refilled introducing the
correct quantity of R134a.

HUMIDITY IN THE

SYSTEM

This defect is Indicated by the partial
frosting of the evaporator and by
continuai defrosting cycles
determined by the interruption of the
flow of gas on the evaporator. The

motor compressor keeps running.

The refrigerant system Is humid
when there is a small percentage of
water present which, not completely

retained by the dehydrator filter,

enters into circulation with the Freon
and freezes at the capillary exit in
the evaporator.

The system must be emptied and
then refilled after eliminating the

humidity.

PRESENCE OF AIR

IN THE SYSTEM

Poor performance of the refrigerant

system which is Indicated: on the
evaporator with a slight frost which
dose not freeze and an excessive
overheating of the condenser and

motor-compressor.

There is air in a refrigerating system
when during the filling phase
vacuum is not effected or it is not
adequately done.

Group must be drained and

subsequently refilled after carefully
creating vacuum.

BLOCKED
CAPILLARY

Because of the lack of circulation
Freon In the system, there is no

frosting of the evaporator, while a
slight overheating of the first spiral of
the condenser is noted.

Eventual impurities contained in the
Freon or in the components of the
refrigeration system before

assembly and not retained by the
filter can obstruct the capillary.

To restore the system it must be
emptied, substitute the capillary or
the evaporator entirely in case the
capillary is coaxial with respect to
the return tube, then refill it.

MOTOR-
COMPRESSOR

SHORT-CIRCUITED

OR BLOCKED

The system dose not work and the
"clixson" intervenes interrupting
delivery to the motor-compressor.

In case of short circuit, the
breakdown is due to the electric

winding: if blocked, there Is a

mechanical failure in the motor-

compressor.

The motor-compressor must be

replaced and then proceed with
refilling.

MOTOR-
COMPRESSOR
DOSE NOT
COMPRESS

No frost forms on the evaporator

even If the motor-compressor is
apparently running regulary.

In this case there is a mechanical

failure in the diaphram valves which:

remaining continually open, do not
permit the piston to suck and

compressor the which
consequentely dose not circulate in
the system.

The motor-corn prossor must be

replaced and then proceed with
refilling.

NOISY MOTOR-
COMPRESSOR

In case of mechanical failure in the
motor-compressor there in an

excessive noise when the system is
functioning: In case a suspension
spring is unhooked, banging will be

heard and there will be especially

strong vibrations when the system
starts up and stops.

The cause of the excessive noise is

normally to be sought for in a
mechanical break down, and only
rarely in the unhooking of one of the

suspension springs.

The motor-corn prossor must be
substituted and then proceed with
the refilling.

10