background image

NO COOLING

The Compressor
doesn't run.

^ Check if the current

flows at the contacting

point of the Thermostat.

Replace the
Thermostat.

Check the current
flowing of starting
system.

Shorted

Broken

Check if the current
flows at the main coil of
the Compressor.

^ Coil shorted

Replace the
Compressor.

Check the components

V Replace the

on the main circuit.

components.

Poor running of the
Compressor.

Measure the starting

voltage.

> Low voltage

Increase the voltage.

Check if the current flows
at the contacting point of
the starting system.

Check if the current
flowing of the sub coil of
the Compressor.

Is the current amount of

the electric components

normal?

Poor contacting point

and broken

> Replace the device.

> Shorted

Replace the
Compressor.

The coil of the
Compressor Motor is

worn out.

Repair the
Compressor.

Compressor runs.

Frost doesn't form at the
Evaporator when

operating set for more
than 30 min.

Refrigerant leaks.
Poor compressing.

Repair the
Compressor.