Jgpiy – Sears 303.147012 User Manual

Page 5

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

O 1 Mark a level line on the supply air plenum (Fig. 6).

Plenum

n 2

Hold case assembly against the plenum with bottom

edge of rear opening on level line. Mark four comers of rectangU'
lar opening and four screw locations on plenum. Screw holes must
be located at end of slot (Fig. 7).

n 3

Connect corner marks to outline rectangular opening.

Center punch four screw locations (Fig. 8].

G 4

Drill or punch a large hole in one corner of rectangle.

This will allow you to insert the tin snips or metal saw.

CAUTION: Be sure not to drill or cut into air conditioning
coil or tubing.

G

5

Cut out the area inside the rectangle. If any of the edges

are rough, file them smooth (Fig, 8).

Q G Drill the four holes marked on the plenum with a 1/8"
drill bit. Holes must be located at end of slot (Fig. 7).

G

7

Attach the humidifier case assembly on the plenum

using 4 #8 screws provided.

Drill 4-

1/8" Holes

Cut Along •

This Line

Cut Out

This Area

Level

Line

Sui

Furnace

jgpiy

Plenum

g

8

Hold collar and flexible tube assembly against cold air

plenum at desired location.

G

3

Mark round opening inside collar and five mounting

holes (Fig. 9).

10

Center punch five screw locations. Drill or punch a large

hole within the round opening. Cut out the area inside the round

opening. Drill the five holes (Fig. 9).

Advertising