Installation – Sears 303.147012 User Manual

Page 7

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Cl

7

Unwind the rest of the tubing. Take care not to kink

it. Run the tubing along flat surfaces to the humidifier. Support the

tubing as needed to avoid contact with furnace.

8

Close previously opened faucet. Turn on main wa­

ter supply. Place a pail under the end of the tubing. Open the

saddle valve. Flush the line. Make sure there are no leaks along

the line or at the valve. Turn valve off.

C

3 With water supply tubing cut to the proper length,

slide the plastic compression nut over the tubing. Slip brass insert
into the end of tubing.

10

Insert the tubing end into the solenoid valve fitting

as far as it will go and hold it there, thread the plastic compression
nut onto the fitting, then tighten securely, finger tight (no wrench).
Do not over tighten nut (Fig. 14).

11

Turn on water supply at saddle valve. Checkfor leale

at solenoid valve fitting and plastic compression nut.

NOTE: water will not flow thru humidifier until electrical in­

stallation is completed.

installation

HUMIDISTAT

The humidistat is designed to mount on the return air plenum of
your furnace or on an interior wall of the home. The return air

plenum, however, is the preferred location for sensing the aver­

age humidity throughout your home and is the location covered
by installation steps 1 through 11. (If you decide on the wall mount
location, the humidistat control unit must be removed and mounted

to the opposite side of the plastic backplate so it will be housed

inside of the plastic cover - omtt shaft e:denslon - purchase addi­

tional low voltage wire and run wire inside of wall to exit hole
within the lower opening of the backplate.)

NOTE: The humidistat as supplied is assembled for return
air plenum installation (Fig. 16.).

RETURN AIR PLENUM MOUNT

□ 1

LOCATE THE HUMIDISTAT on return air plenum

(Fig. 15). DO NOT install humidistat on supply air plenum.
HUMIDISTAT MUST BE MOUNTED AT LEAST 6" UPSTREAM
FROM FLEXIBLE HOSE (OR HUMIDIFIER IF HUMIDIFIER
INSTALLED ON RETURN AIR PLENUM).

2

HUMIDISTAT

MOUNTS

IN

A

HORIZONTAL

POSI­

TION. Peel paper backing from template and paste it on return

air plenum \^ere humidistat is to be mounted. Keep level.

O 3

Drill 1/8" holes for the four mounting screws as

shown on the template.

□ 4

Cut out center portion of template within solid lines.

C

5

After removing paper backing from gasket, apply

gasket around return air plenum opening as indicated on tem­
plate (Rg. 16).

Apply Gasket Here Around Opening

Backplate

Mounting \

Screws V Ч

(4) \

Cover-

/

Return Air

Plenum

Opening

Knob

Control Unit

Control Mounting

Screws (2)

Shaft Extension