FIG. 17

WIRING INTO FURNACE

(For Fumaco with 120 VAC Singte Speed Blower Motor only)

•Humidistal

Furnace

Blower

Cmtrol

WHT.

Furnace

Blower

/\

Motor 120 VAC->-(

Single Speed V/

y

- -

WIRING TO CONSTANT 120 VAC UNE

EXTERNAL TO FURNACE

6

Using low voltage wire supplied, connect spade ter­

minals to solenoid valve on top of humidifier.

Q 7

Position and support wire to humidistat location.

Separate wire. Cut only one wire, strip ends.

O 8 Feed wires thru opening in humidistat back plate

and attach to screw terminals. Mount humidistat on return air ple­
num using (4) #8 screws provided. Install shaft extension, cover

and knob (Fig. 16).

CONTROL CIRCUIT: For proper operation and water conserva­
tion, this humidifier must be wired so it will operate only when the

furnace blower is running and the humidistat calls for additional

humidity. Two methods are shown (Fig. 17 and Fig. 18):

Fig 17: WIRING INTO FURNACE - FOR ANY FORCED AIR
FURNACE WITH SINGLE SPEED 120 VAC BLOWER ONLY.

CAUTION: Do not use this method with multi-speed blow­
ers or blowers other than 120 VAC.

Fig 18: WIRING EXTERNAL TO FURNACE - FOR ANY FORCED

AIR FURNACE INCLUDING FURNACE WITH OTHER THAN 120
VAC BLOWER MOTOR OR FURNACE WITH MULTI-SPEED
BLOWER MOTOR.

NOTE: Some furnaces are equipped with accessory termi­

nals that can be used for the humidifier. In this case, consult
the furnace manufacturer’s recommendation for wiring.

□ 9

_ Turn off electricity at fuse box. Using (two) wire nuts

and conduit nut supplied, install 24 VAC transformer to 120 VAC

supply junction box following the control oircuit selected so the

transformer will be powered only w^en the furnace blower is run­

ning. Do not use existing transformer on furnace.

10

Connect spade terminals of low voltage wire to

spade terminals of treinsformer.

11

Turn on electricity and test operation by observing If

water is flowing to drain while furnace is running arid humidistat
dial is set to “tesT position.

Salt Switch

-24 VAC

Transformer

Purchase this accessory! _____

Available from Sears Product J

Phot»: 1-SOO-366-7278

Specify Division 42 PLS042 PI, No. 9114

NOTE: Wiring must conform to local codes.

12

Attach “Operating Instruction LabeT to return air ple­

num next to the humidistat. Peel off paper backing and stick l£d>el
in desired location.

operation

1

Set knob to the lowest temperature predicted for a

24 hour period. Because of differences in house construction you
may want to tiy a higher or lower setting to adiieve proper humidity.

n 2

Change

knob

settings

as

outdoor

temperature

changes occur.

WARNING: DO NOT LEAVE KNOB SET IN “TEST POSI­
TION ABOVE “+20" OR HUMIDIFIER WILL RUN CON­

STANTLY.

IF SWEATING OF WINDOWS OR WALLS OCCURS OR IF AIR
IS TOO DRY:

Check dial setting. Indicator should point to the lowest 24 hour

temperature. If setting does not agree, readjust knob to proper

number and wait 24 hours for sweating to stop. If dial setting was

correct and conditions have not changed, rotate knob back and

forth from TEST to MINIMUM HUMIDITY SETTING. If humidifier
goes ON and OFF, control is operating properiy.

AIR CONDITIONING - IMPORTANT:

If your furnace has air conditioning (cooling), close the damper

completely during summer months and turn the humidistat to the

Minimum Humidity setting. BE SURE TO OPEN DAMPER DUR­

ING HEATING SEASON AND RESETTHE HUMIDISTAT.

WATER FLOW RATE:

At standard water line pressure of 50-60 PSI (pounds per squEkre

inch), water will flow through humidifier at approximately four (4)
gallons per hour. About 0.7 gallons per hour of the four wilt be

evaporated, leaving 3.3 gallons to be drained away. Since the fur­

nace only runs an estimated 30-40% of the heating season, and

the-humidifter is wired to operate only with №e furnace blower,
and only when humidity is required, the actual amount of water
drained per day is much less than would be expected.