Awarning, Sediment trap, Gas piping with flexible connector – Sears 153.33645 User Manual

Page 15: Gas piping with all black iron pipe to gas control, Installation instructions (cont’d)

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Installation Instructions (cont’d)

AWARNING

The appliance and its gas connection must be leak tested
before placing the appliance in operation.

AWARNING

• The appliance and its individual shutoff valve must be discon­

nected froni the gas supply piping system during any pressure

testing of the gas system at test pressures in excess of

%

pound per square inch (3JkPa).

»The appliance must be isolated from the gas supply piping sys­

tem by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test pres­
sures equal or less than '/i pound per square inch (3.5kPa).

AWARNING

Use pipe Joint compound or teflon tape marked as being
resistant to the action of petroleum [Propane (L.P.)] gases.

SEDIMENT TRAP

A. sediment trap stall be installed as close to the inlet of the

rater heater as practical at the time of water heater installation.

The sediment trap shall be either a tee fitting with a capped nip­

ple in the bottom outlet or other device recognized as an eftcc-
tive sediment trap. If a tee fitting is used, it shall be installed in
conformance with one of the methods of installation shown
below.

Connecting the gas piping to the gas control valve of the water
heater can be accomplished by either of the two methods shown.

AWARNING

Contaminants in the gas lines may cause improper operation
of the gas control valve that may result in fire or explosion.
Before attaching the gas line be sure that all gas pipe is clean

on the inside. To trap dirt or foreign material in the gas
supply line, a drip leg (sometimes called a sediment trap)
must be incorporated in the piping. The drip leg must be
readily accessible. Install in accordance with the “Gas Piping”
section. Refer to the latest edition of the National Fuel Gas
Code, ANSI Z223.1, also referred to as NFPA 54.

GAS PIPING WITH

FLEXIBLE CONNECTOR

GAS SUPPLY

PIPING

FLEXIBLE GAS CONNECTOR

GAS PIPING WITH ALL BLACK IRON

PIPE TO GAS CONTROL

GAS SUPPLY

PIPING

15