Installation checklist, Installation instructions (cont’d) – Sears 153.33645 User Manual

Page 16

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Installation Instructions (cont’d)

Installation Checklist

BEFORE LIGHTING THE PILOT;

• Check the gas lines for leaks.

a. Use a soapy water solution. DO NOT test for gas leaks

using a match or open flame.

b. Brush the soapy water solution on all gas pipes, joints and

fittings.

c. Check for bubbling soap. This means you have a leak.

Turn “OFF” gas and make the necessary repairs.

d. Recheck for leaks.
e. Rinse off soapy solution and wipe dry.

» Is the new teinperature-pressure relief valve properly installed

and piped to an adequate drain? See “Temperature-Pressure
Relief Valve” section.

* Are the cold and hot water lines connected to the water

heater correctly? See “Water Piping” instructions in the
“Installation Instructions” section,

• Is the water heater completely filled with water? See “Filling”

instructions in the “Installation Instructions” section.

» Will a water leak damage anything? See the “Facts to

Consider About the Location” section.

♦ Is there proper clearance between the water heater and any­

thing that might catch fire? See the “Facts to Consider About
the Location” section,

» Do you have adequate ventilation so that the water heater

will operate properly? See “Combustion Air and Ventilation”

in the “Installation Instructions’ section.

* Is the draft hood vent piping properly secured? See “Venting”

instructions in the “Installation Instructions” .section.

* Is there proper clearance between the vent pipe and anything

that might catch on fire? Sec “Venting” instructions in the
“lastallarion Instructions” section,

» Is the vent pipe properly sloped and docs the vent terminate

outdoors? See “Venting” instructions in the “Installation
Instructions” section.

» Do you need to call your gas company to check the gas pipe

and its hookup?” section.

VENT PJPl TO

OUTDOORS

OR CHIMNEY

SHUTOFF VALVE

COLO

GAS SUPPLY

TEMPERATURE-

PRESSURE

RELIEF VALVE

DISCHARGE PIPE

(Do not cap or plug)

SHUTOFF VALVE

TEE

DRIP LEG

(Sediment trap)

CAP-

DRAIN VALVE

WATER HEATER

GAS BTU/HR. QAL,rHR,

MAWiihjM HyCfflOSTATiC QAS PRESSURE IN W.G.

WOfWNfl 3A«r, INLET MIfi, iMtêt PSESaURE MiWJ8R3ti3

150

MODEL RATING PLATE

16

Advertising