Bias and Recording Level Calibration (122 MKIII only)

si ^

vl/

-Or

^

\ t ✓

->0'*^CORD

• ■

\ly

^ ©

L LEVEL R

© ©

O

I 1QkHz~~j

Tapes differ considerably in the bias required to record on them and in their

sensitivity. The 122 MKIII allows fine adjustment of bias to exactly match the
tape being used ; also the reference recording level can be precisely adjusted to
compensate for difference in sensitivity among tapes.

■ Before starting adjustment, clean the heads, tape guides, rollers, etc. and

demagnetize the heads and all metal parts in the tape path.

■ In you intend to make adjustment while monitoring through speakers, turn

down their volume to avoid damage to them.

■ Have at hand a crisscross screwdriver which fits in with the BIAS/LEVEL

trimmers.

1. Load the tape.

2. Make the following settings :

INPUT

level controls to 0 ;

OUTPUT

level control to 0 ;

MONITOR

switch to AUTO ;

DOLBY NR

switch to OFF ;

MPX FILTER

to OFF.

3. Press

PLAY

and

RECORD

to put the deck into Record mode.

4. Press

ADJUST,

then press

OSC.

5. Turn the

BIAS

trimmers all the way to the left with the appropriate screwdriver.

6. Slowly turn the

BIAS

trimmers (one at time) clockwise for maximum reading

on the VU meters.

Suggestions : Turn the trimmers to the left and right alternately to "pinpoint"
the exact maximum position. If the meter needles deflect all the way to the
right, adjust the LEVEL trimmers until the meters read about 0 VU at a

maximum setting of BIAS.

7. Adjust the

LEVEL

trimmers (one at time) for 0 VU.

8. While alternating the oscillator signal between 10 kHz and 400 Hz by pressing

the

10 kHz

switch on and off (still in record mode), adjust the

BIAS

trimmers

so that the VU meters show almost the same reading at both frequencies.

9.

Set the oscillator to 400 Hz (10 kHz LED off) and readjust the

LEVEL

trimmers for 0 VU.

Repeat the procedure each time you change the tape, especially when you change
the type of tape.