background image

iDP-3420/3421/3423 User’s Manual

50

CITIZEN

10

10

10

10....3333....2222 D

D

D

Daaaatttta

a

a

a C

C

C

Coooonnnnffffiiiigggguuuurrrraaaattttiiiioooonnnn

t

Mark

b

0

, b

1

, b

2

, · · · ·

Space

(1)

(2)

(3)

(1) Start Bit
(2) Data Bit (+ Parity Bit)
(3) Stop Bit (1 or More)

(1) Start bit

After a lapse of 1/2 bit from a mark-to-space fall edge, the state is read again, and if it is
a space, it is recognized as the start bit. If it is a mark, it is assumed neither the start
bit nor an error, and it is attempted to detect the start bit again.

(2) Data bit + parity bit

The data bit and parity bit are sampled for 1 bit worth of time from the 1/2 start bit.
The then state is assumed the data for the corresponding bit. A sequence of the bits are
named Bit 0, Bit 1, ..., parity bit, starting from the one closest to the start bit.

(3) Stop bit

The stop bit is a mark level of 1 bit or more. If a space is detected in detecting the stop
bit, a framing error results.