Ozone, Freeze protection, Periodic reminder messages – Cal Spas LTR20051000 User Manual

Page 32: Diagnostic messages

Advertising
background image

Operating Your Spa

Page 28

2005 Spa Owner's Manual

8/1/2005

Ozone

This is an optional feature. On most systems, the ozone generator (if installed) runs during filter cycles (except
when pump 1 is operating at high speed on a non-circ system) and during clean-up cycles. On some systems,
the ozone generator operates whenever the pump runs. If your system is configured with the optional ozone
disable feature, the ozone generator will turn off for one hour any time a function button (JETS 1, JETS 2,
OPTION etc.) is pressed.

Freeze Protection

If the temperature sensors detect a drop to 44°F within the heater, the pump automatically activates to provide
freeze protection. The equipment stays on until four minutes after the sensors detect that the spa temperature has
risen to 45°F or higher. In colder climates, an optional additional freeze sensor may be added to protect against
freeze conditions that may not be sensed by the standard sensors. Auxiliary freeze sensor protection acts
similarly except with the temperature thresholds determined by the switch and without a four minute delay in
turnoff.

Periodic Reminder Messages

Press the “Mode” button to reset a displayed reminder.

Message Frequency

Action

Required

rPH

Every 7 days

Test and adjust chemical levels per manufacturer’s
instructions.

rSA

Every 7 days

Test and adjust chemical levels per manufacturer’s
instructions.

rCL

Every 30 days

Remove, clean, and reinstall filter per
manufacturer’s instructions.

rtg

Every 30 days

Test and reset GFCI per manufacturer’s instructions.
Drain and refill spa per manufacturer’s instructions.

rdr

Every 90 days

Drain and refill spa per manufacturer’s instructions.

rCO

Every 180 days

Clean and condition spa cover

rCH

Every 365 days

Install New Bio-Clean™ Filter

WARNING! SHOCK HAZARD!

There are no user serviceable parts. DO NOT attempt service of this control system. Contact your dealer

or service center for service.

Diagnostic Messages

Message Meaning

Action

Required

No message on display. Power has
been cut off to the spa.

The control panel will be disabled until power
returns. Spa settings and time of day will be
preserved for 30 days with a battery back-up;
settings only are preserved until the next power-up
on 9800 systems.