Caution, Maintenance instructions – Poulan PPBP30 User Manual

Page 13

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

7 -

MAINTENANCE INSTRUCTIONS

7-2. AIR FILTER

CAUTION

NEVER operate blower without the

air filter. The air filter must be kept clean. If It becomes da­

maged. install a new filter.

TO CLEAN AIR FILTER:

1.

Loosen knob (A) holding air filter cover In place,

remove cover (B) and lift filter (C) from air box (Fig. 7-

2A a Fig. 7-28).

2.

\A/ash filter in soap and water. DO NOT USE GASO­

LINE!

3.

Air dry filter.

4.

Reinstall filter,

NOTE: Replace filter if frayed, torn, damaged or unable to

be cleaned.

7-2B

7-3. FUEL CAP

/

FUEL FILTER

CAUTION

Remove fuet from unit and store in approved container

before starting this procedure. Open fuel cap slowly to

release any pressure which may have formed in fuel tank.

FUEL FILTER:

f, Completely remove fuet cap (A) from fuet tank (B) to

allow removal of the fuel filter (D) from tank. Use a

piece of wire (C) with a hook formed at the end to pull

fitter out of tank, (Fig. 7-3A & 7-3B},

2.

Pull filter (0) off with a twisting motion, (Fig, 7-3C)

3.

Replace fuel filter (D). (Fig, 7-3C)

NOTE: Never operate the blower without the fuel filter.
Internal engine damage could result!

7-3C

13

Advertising