18

REMOTE

CONTROL

CHANNEL

NUMBER

A second remote control can be purchased from your dealer to provide
dual remote control of one fan. Because the fan could be confused by
two controllers signaling different information it is necessary to set a
BASE control and an AUXILIARY control.
The last control manually operated controls the fan.

Where two remote controls are used to control a single fan, they must
be set so that:
• BOTH controls are set to the SAME channel.
• ONE control is made into the BASE control.
The OTHER control is made an AUXILIARY control.
(All remote controls leave the factory as a BASE).
Initial remote control settings
1. Set both the controls to operate the fan.
2. Select one of the remote controls to be the BASE unit.

BASE Check
To confirm that the control is the BASE:
1. Press

for 3 seconds until a beep is

heard.

2. Confirm temperature display shows 'b'.
3. Press

again to set.

BASE

DISPLAY

AUXILIARY

DISPLAY

Note: Always change the remote control channel
first. The fan channel can only be changed by
having the desired channel already set in the re-
mote control.

COMFORT•TOUCH DUAL REMOTE CONTROL - BASE

COMFORT•TOUCH DUAL REMOTE CONTROL - AUXILIARY

TWO CONTROLS OPERATING ONE FAN

When two controls are used for the same fan, we suggest that both controls be set for the same features
(AUTO-SPEED, SAVER, etc.) so that performance remains the same as you move from one to the other. Re-
member, the fan will only respond to updates from the control that was last operated manually.

Change the other remote to be used in the room to AUXILIARY
1. Press

until a beep is heard. Remote displays 'b'.

2. Press fan up

or down

buttons to change the display to 'A'.

3. Press

again to set.

The fan will now respond to either of the remotes when pressed.

• Reminder! These steps will have to be repeated whenever the

batteries are changed.

• When AUTO-SPEED, SECURITY, SAVER or TEST modes are in ef-

fect at any control: Automatic control will only be from the
control that was last operated manually.

Do not reset the channel on other fans in
your home during this 110 second period.

COMFORT•TOUCH CHANGING CHANNELS - FAN

The control automatically changes the fan
channel to the new setting.

Changing the control channel
1. Hold the

button down until a tone is heard.

2. The temperature display will show the current channel number.
3. Press fan up

or down

buttons to change the number to a

unique number from 49 to 63.

DO NOT use other channel numbers.

4. Push

to return to normal operation.

You will need to repeat this step any time you remove the remote
control batteries. Record the new channel setting in the space pro-
vided on the rear label.

1. Turn OFF power to the fan for five seconds or longer using the wall

switch or circuit breaker.

2. Turn the power back ON.

WAIT 20 SECONDS.
You have 90 seconds in which to complete step 3.

3. Press and hold the

and

buttons together until the

display shows 'cc' (for Change Channel), then release.

COMFORT•TOUCH CHANGING CHANNELS - CONTROL