9.4  Pressure and leakage checks 

Check the following parts of the coffee machine for leakages: 

• 

Compact brewing unit 

• 

Hose connections 

• 

Thermoblock 

• 

Pump 

• 

Self priming device 

8)  Switch on coffee machine. 
9)  After heating up, press the "small cup" 

button. 

10) Open the valve until water begins to 

flow. 

11) Close the valve until the pressure 

gauge indicates 12 bar. 

Constantly monitor the pressure 
gauge and if required readjust the 
valve. As the temperature 
increases, so does the pressure, 
readjust the pressure to 12 bar 
when required. 

12) Carry out measurement for approx. 

30 sec. 

13) Control measuring cup: at least 60­ 

120 ml of water must be in the measur­ 
ing cup. 

14) Open the valve and let water flow out 

of the pressure tester. 

Notices: 

• 

Should < 60 ml leak out, then the pump 
is defective or there is a leak in the 
water system. 

• 

Large deviations in indicated pressure 
while measuring (± 4 bar) means that 
the pump is defective. 

Dangerous mains voltage inside the coffee machine! 
Do not touch any parts under voltage while checking for leakages! 

Dangerous hot parts under pressure inside the coffee machine! 
Do not touch any hot/pressurized parts while checking for leakages! 
Always wear protective goggles.