F U N C T I O N T E S T S
9.4 Pressure and leakage checks
Check the following parts of the coffee machine for leakages:
•
Compact brewing unit
•
Hose connections
•
Thermoblock
•
Pump
•
Self priming device
8) Switch on coffee machine.
9) After heating up, press the "small cup"
button.
10) Open the valve until water begins to
flow.
11) Close the valve until the pressure
gauge indicates 12 bar.
Constantly monitor the pressure
gauge and if required readjust the
valve. As the temperature
increases, so does the pressure,
readjust the pressure to 12 bar
when required.
12) Carry out measurement for approx.
30 sec.
13) Control measuring cup: at least 60
120 ml of water must be in the measur
ing cup.
14) Open the valve and let water flow out
of the pressure tester.
Notices:
•
Should < 60 ml leak out, then the pump
is defective or there is a leak in the
water system.
•
Large deviations in indicated pressure
while measuring (± 4 bar) means that
the pump is defective.
Dangerous mains voltage inside the coffee machine!
Do not touch any parts under voltage while checking for leakages!
Dangerous hot parts under pressure inside the coffee machine!
Do not touch any hot/pressurized parts while checking for leakages!
Always wear protective goggles.