DLP- E176 Edit Path Protection Dual-Ring Interconnect Circuit Hold-Off Timer

DLP-E176 Edit Path Protection Dual-Ring Interconnect Circuit Hold-Off Timer

Note

Cisco recommends that you set the DRI port HOT value to zero and the circuit path selector HOT value
to a number equal to or greater than zero.

Step 1

From the View menu, choose Go to Network View.

Step 2

Click the Circuits tab.

Step 3

Click the path protection circuit you want to edit, then click Edit.

Step 4

In the Edit Circuit window, click the Path Protection Selectors tab.

Step 5

Create a hold-off time for the circuit source and destination ports:

a.

In the Hold-Off Timer area, double-click the cell of the circuit source port (top row), then type the
new hold-off time. The range is 0 to 10,000 ms in increments of 100.

b.

In the Hold-Off Timer area, double-click the cell of the circuit destination port (bottom row), then
type the hold-off time entered in Step

a.

Step 6

Click Apply, then close the Edit Circuit window by choosing Close from the File menu.

Step 7

Return to your originating procedure (NTP).

Purpose

This task changes the amount of time a path selector switch is delayed for
circuits routed on a path protection dual-ring interconnect (DRI) topology.
Setting a switch hold-off time (HOT) prevents unnecessary back and forth
switching when a circuit is routed through multiple path protection
selectors.

Tools/Equipment

None

Prerequisite Procedures

NTP-E35 Provision Path Protection Nodes, page 5-17

DLP-E26 Log into CTC, page 16-33

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Advertising