Bryant FA4A User Manual

Page 11

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

A U G / 1 4 / 2 0 0 8 / T H U 0 3 : 4 7

UTC TECH PUB

F A X N o , 3 1 7 2 4 0 5 6 6 2

0 1

TABLE

3—MALE/FEMALE

QUICK-CONNECT TERMINALS

SIZE FEMALE

SIZE MALE

DESCRIPTION

M2

Motor line voltage connection (230 vac 60 Hz)

T3

Transformer line voltage connection (230 vac go Hz)

T2

Transfomior tap storage terminal for 208-vac lead

0.250 X 0.032

SEC1

Secondary connection from transformer (24 vac)

This connection is common to chassis ground through sydet marked GROUND SCREW REQUIRED,

SEC2

Secondary connection from transformer (24 vac)

HUM1

Low voltage ground for humidifier option (24 vdc)

HUM2

Low voltage output for humidifier option (24 vdc)

AUX1

Low voltage ground for auxiliary option (24 vdc)

AUX2

Low voltage output for auxiliary option (24 vdc)

Ml

Common connection to blower motor

0.187 X 0.032

T1

Common connection for transformer

REd I

Common to R screw terminal and SEC2

TABLE 4™C0NNECTI0NS ON SINGLE BARRIER S

tr

IR MOUNTED, CROSS SLOTTED, CAPTIVE BINDING HEAD

SCREW

TERMINAL

DESCRIPTION

W2

Connection fbr W2 signal from thermostat

W3

Connection for W3 signal from outdoor thermostat

E

Connection for E signal from thermostat

Y/Y2

Connection for Y signal from thermostat

G

Connection for G signal from thermostat

0

Connection for 0 signal from thermostat

L

This connection Is a field termination for use in connecting L lines of thermostat and outdoor unit together. Thare is no

connection of this terminal with control circuity.

Y1

Connaction for low-speed compressor operation

R

Connection for R signal to tharmostat (24 vac)

C

Connection for C terminal to thermostat (24 vac common)

TABLE 5—CONNECTIONS AND CONNECTOR

TYPE

CONNECTION

TYPE

CONNECTOR

PIN NO.

DESCRIPTION

Pin 1

Common to E screw terminal

Pin 2

Common to W2 screw terminal

Pin 3

Common to C screw terminal, SEC1 terminal, and chassis ground

Pin 4

Common to C screw terminal, SEC1 terminal, and chassis ground

Pins

No connection

Heater

12-Pln

Pin 6

Common to W3 scraw terminal

Connection

Pin?

Common to M2 and T3 quick-connects, 230 vac input

Plh'B

No connection

Pin 9

Common to Mi and T1 quick-connects, 230 vac input

Pin 10

No connection

Pin 11

No connection

Pin 12

No connection

Pin 1

Diode OR output of E or W3 or W2 thermostat signals

Pin 2

Thermostat G signal

Pin3

Common to C, SECI, and chassis ground

ICM2 Motor

7-Pin Header

Pin 4

Common to C, SEC1, and chassis ground

Pins

Common to R and SEC2 (via 5-amp fuse)

Pin 6

Thermostat Yrir2 signal

1

Pin?

Thermostat Y1 signal

receiving correct voltage, replace sequencer. If sequencer is
dosing, check high-voltage wiring as discussed in items 1
and 2.

IF THERE ARE BLOWN DIODES:

If diodes are blown, it is probable electric heater plug is miswired.

Correct miswiring.

NOTE: Board will need to be replaced if diode is bad.

IF TRACES ARE OVERHEATED ON BACK OF PQB;

Usually whenever there js a trace blown on PCB, it means cither

there has been a high-voltage short or high voltage has been

applied to low-voltage circuit. This can be prevented by making

sure PCB is wired correctly before PCB has power applied to it.

-11-