16

Invisible Light Beam
Protection Area

Sensor

Sensor

Safety Reversing Sensor

Bell Wire

Bell Wire

Motor unit

Safety Reversing Sensor

Power Door Lock

Quick-Connect Terminals

WHT/BLK

WHT

WHT/RED

WHT

Sensor
Connections

To Power
Door Lock

To CableTension Monitor

To Door Control

Connect Wire to
Quick-Connect
Terminals

Carriage Bolt
1/4"-20x1/2"

Lens

Wing Nut
1/4"-20

Figure 5

Figure 6

MOUNTING AND WIRING THE SAFETY REVERSING
SENSORS

• Slide a 1/4"-20x1/2" carriage bolt head into the slot on

each sensor. Use wing nuts to fasten safety reversing
sensors to brackets, with lenses pointing toward each
other across the door. Be sure the lens is not obstructed
by a bracket extension (Figure 5).

• Finger tighten the wing nuts.

Run the wires from both safety reversing sensors to the

opener. Use insulated staples to secure wire to wall
and ceiling.

• Strip 7/16" (11 mm) of insulation from each set of wires.

Separate white and white/black wires sufficiently to
connect to the opener quick-connect terminals: white to
white and white/black to grey (Figure 6).

ALIGNING THE SAFETY REVERSING SENSORS

Plug in the opener. The indicator lights in both the

sending and receiving eyes will glow steadily if wiring
connections and alignment are correct.

The sending eye amber indicator light will glow regardless
of alignment or obstruction. If the green indicator light in
the receiving eye is off, dim, or flickering (and the invisible
light beam path is not obstructed), alignment is required.

• Loosen the sending eye wing nut and readjust, aiming

directly at the receiving eye. Lock in place.

• Loosen the receiving eye wing nut and adjust the safety

reversing sensor until it receives the sender’s beam.
When the green indicator light glows steadily, tighten the
wing nut.

TROUBLESHOOTING THE SAFETY REVERSING
SENSORS

1. If the sending eye indicator light does not glow steadily

after installation, check for:

• Electric power to the opener.

• A short in the white or white/black wires. These can

occur at staples, or at opener connections.

• Incorrect wiring between safety reversing sensors and

opener.

• A broken wire.

2. If the sending eye indicator light glows steadily but the

receiving eye indicator light doesn't:

• Check alignment.

• Check for an open wire to the receiving eye.

3. If the receiving eye indicator light is dim, realign

either sensor.

NOTE: When the invisible beam path is obstructed or
misaligned while the door is closing, the door will reverse.
If the door is already open, it will not close.
The remote lights will blink 10 times. (If bulbs are not
installed, 10 clicks can be heard.) See page 11.