Planning – Chamberlain 3800P User Manual

Page 3

Advertising
background image

Safety
Reversing Sensor

Safety
Reversing
Sensor

Torsion Spring

Motor unit

Wall-mounted
Door Control

Access Door

Gap between floor
and bottom of door must not exceed 1/4" (6 mm).

Power
Door Lock

Cable Tension
Monitor

Remote Light

Drum

3

Planning

Survey your garage area to see if any of the conditions
below apply to your installation. Additional materials may
be required. You may find it helpful to refer back to this
page as you proceed with the installation of your opener.

Depending on your requirements, there are several
installation steps which may call for materials or hardware
not included in the carton.

This opener is compatible with:

• Doors that use a torsion bar, springs and a door no

more than 14' (4.2 m) high.

• 4"-6" (10 cm - 15 cm) drums, not to be used on tapered

drums over 6" (15 cm).

• High lift and standard lift sectional doors up to 14'

(4.2 m) high.

• Doors up to 18' (5.4 m) wide.

• Doors up to 180 sq. ft. (16.7 sq. m).

• 1" (2.5 cm) torsion bar only.

• Review or inspect proposed installation area. Opener

can be installed on left or right side of door. Select the
side that meets the requirements listed below.

- Must have minimum of 2-1/2" (6.4 cm) between the

garage wall and the center of the torsion bar.

- Must have minimum of 3" (7.6 cm) between the ceiling

and the center of torsion bar.

- Must have minimum of 8" (20.3 cm) between the side

garage wall (or obstruction) and the end of torsion bar.

• The torsion bar must extend at least 1" to 5"

(2.5 cm to 12 cm) past the bearing plate.

• An electric outlet is required within 6' (1.8 m) of the

installation area. If outlet does not exist, contact a
qualified electrician.

• Depending upon garage construction, extension

brackets or wood blocks may be needed to install safety
reversing sensors.

• Alternate floor mounting of the safety reversing sensors

will require hardware not provided.

• A model 475LM EverCharge

TM

Battery Backup System is

strongly recommended if there is no access door to the
garage, as this opener cannot be used in conjunction
with an external emergency release mechanism.

• Any gap between the floor and the bottom of the door

must not exceed 1/4" (6 mm). Otherwise the safety
reversal system may not work properly.

NOTE: Inspect the torsion bar while the door is raised and
lowered. It is important that there is no noticeable
movement up and down or left and right. If this type of
movement is not corrected, life of this opener will be
greatly reduced.