Attach the emergency release rope and handle, Install power door lock, Installation step 3 – Chamberlain 3800P User Manual

Page 8: Installation step 2

Advertising
background image

Staples

Lock Screw
1/4-20 x 1/2" (2)

HARDWARE SHOWN ACTUAL SIZE

Approx. 3" (7.6 cm)

Lock Template

Roller

Garage
Door Track

TOP

DRILL 5/16"

DRILL 3/4"

DRILL 5/16"

132A2505

TOP

DRILL 5/16"

DRILL 3/4"

DRILL 5/16"

132A2505

Figure 1

INSTALLATION STEP 3

Install Power Door Lock

The lock is used to prevent the garage door from
being manually opened once the door is fully closed.

1. Select a door roller to mount the lock above. Check for

clearance. If possible select a roller on the same side of
the door as the motor unit. The second roller up from
the bottom is ideal in most installations.

2. Ensure rail surface is clean and adhere lock template

with bottom edge just above the highest point on the
roller (Figure 1).

3. Drill holes as marked on the template.

4. Fasten power door lock to the outside of the garage

door track with hardware provided.

5. Run bell wire up wall to motor unit. Use insulated

staples to secure wire in several places.

6. Plug connector into the motor unit (Figure 2).

NOTE: Lock must be mounted within 10' of the power
head.

NOTIC

E

Overhand
Knot

Emergency
Release Handle

Overhand
Knot

Rope

Motor Unit

Emergency
Release Cable

To prevent possible SERIOUS INJURY or DEATH from a falling
garage door:
• If possible, use emergency release handle to disengage door

ONLY when garage door is CLOSED. Weak or broken springs
or unbalanced door could result in an open door falling
rapidly and/or unexpectedly.

• NEVER use emergency release handle unless garage

doorway is clear of persons and obstructions.

INSTALLATION STEP 2

Attach the Emergency Release Rope
and Handle

• Thread one end of the rope through the hole in the top

of the red handle so “NOTICE” reads right side up as
shown. Secure with an overhand knot at least 1"
(2.5 cm) from the end of the rope to prevent slipping.

• Thread the other end of the rope through the loop in the

emergency release cable.

• Adjust rope length so the handle is no higher than 6'

(1.83 m) above the floor. Secure with an overhand knot.

NOTE: If it is necessary to cut the rope, heat seal the cut
end with a match or lighter to prevent unraveling.

Figure 2

8