SPECIFICATIONS—UNITS WITH ELECTRIC HEATER

MODEL

517G

SIZE

N048075 I N 0 4 8 0 1 0

P048010

N048012

N048015

P048015

P048018

1 RATINGS & PERFORMANCE

Nominal Capacity (Btuh)»

48,000

48,000

48,000

48,000

48,000

48,000

, -48,000

Nominal Airflow (Fts/Min)t

1600

1600

1600

1600

1600

1600

1600

Electric Heating Output (KW)t

7.5

10.0

10.0

12.0

15.0

15.0

18.0

Electric Heating Capacity (MBtuh)t

19.2/23.5

25.6/31.3

25.6/31.3

30.8/37.6

38.5/47.0

38.5/47.0

46.1/56.4

1 ELECTRICAL

Unit Voits—Phase (60 Hz)

208/230-1

208/230-1

208/230-3

208/230-1

208/230-1

208/230-3

208/230-3

Operating Voltage Range

187-253

187-253

187-253

187-253

187-253

187-253

187-253

Internal Circuit Protection»»

None

None 1 CBtt

None

Fuses

Fuses

CBtt

None

None

Single-Circuit Operation

Rated Load Amps

31.8/34.8

40.8/44.8

25.6/27.6

48.2/52.8

58.8/64.8

36.0/39.5

42.4/46.4

Minimum Ampacity for Wire Sizing

40.8/44.5

52/57

33/35.75

61.25/67

74.5/82

46/50.4

54/59

Minimum Wire Size»»»

8/8

6/6

8/8

6/4

6/4

_

6/6

6/6

Maximum Wire Length (Ft)»»»

92/93

112/113

140/144

95/151

78/123

156/157

132/134

Maximum Fuse Size (Amps)

45/45

60/60

35/40

70/70

80/90

50/60

60/60

Dual-Circuit Operation

Rated Load Amps LI & L2

33.7/36.8

40.8/44.8

L 3 & L 4

14.5/16

18/20

Minimum Ampacity for Wire Sizing

LI &L2

43.1/47

52/57

L3 & L4

-

18/20

22.5/25

Minimum Wire Size»»» LI. & L2

8/6

6/6

L 3 & L 4

-

-

12/12

10/10

Maximum Wire Length (Ft)»»» LI & L2

87/137

112/113

L 3 & L 4

_

80/80

102/102

_

Maximum Fuse Size (Amps) LI & L2

45/50

60/60

■ —

L 3 & L 4

20/20

25/25

Control Transformer—24V (VA)

60

60

60

60

60

60

60

INDOOR COIL

Rows & Fins Per Inch

3 & 1 3

Height X Width (In.)

3 2 . 5 x 2 2 . 8

Face Area (Sg Ft)

5.1

R-22 Refrigerant Metering Device

Check-Flo-Rater

Piston ID Number

82

Condensate Drain Connection (Pri-Sec)

3/4 MPT-3/4 FPT

INDOOR BLOWER & MOTOR

Wheel Diameter x Width (In.)

1 0 x 9

Filter Size—Cleanable (In.)

20 X 25 X1

Blower Motor HP

1/2

Blower Motor Speeds & Type

3 & DD(PSC)

Rated Load Amps

4.8

OPTIONAL EQUIPMENT (P/N’S)

Liguid-Tube Swivel Ell (3/8)tt

P651-1066

Vapor-Tube Swivel Ell (3/4)tt

P651-1068

Single-Circuit Kit»»

1 1 i 301820-4001

\

= 1

»See condensing unit or heat pump outdoor section PDS for cooiing and/or heating capaoity ratings with 517G Fan Coils.
fSee air delivery table in this PDS.
tKW values shown are nominal rated heater outputs at 240V and do not include blower motor heat. Capacity values shown are calculated using KW

outputs at 208V/230V.

»»Single-phase 10-, 15-, or 20-KW electric heaters have the internal circuit protection options shown. Single-phase 12-, 15-, or 20-KW heaters are

wired for dual-oirouit operation. The optional single-circuit kit may be field-installed in units with a 12-, 15-, or 20-KW single-phase fused heater for
single-circuit operation.

ttCB = circuit breakers.
ttUsed for right-angle refrigerant connections to the coil.

»»»Wire sizes and lengths are based on copper conductor at 86 ° F (30 ° C) ambient temperature and ampacity shown in table. Insulation must be 90 ° C

on conductor used between the disconnect switch and the heater and at least 75 “ C on the conductor used between the disconnect and the serv­
ice panel. If other than copper oonductor is used, or is ambient temperature is above 86 °F, determine wire size from ampacity shown and the Na­
tional Electrical Code. Wire lengths shown are measured one way along the wire path between the disoonnect and service panel for minimum 2%

voltage drop.