Optional field-installed electric heat packages – Bryant 517G User Manual

Page 7

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

AIR DELIVERY (Ft^/Min) AT INDICATED EXTERNAL STATIC PRESSURE (With Filter)

517E

Size

Motor

Speed

Tap

Coil

-

External Static Pressure —Inches wc

0.1

0.2

0.3

0.4

0.5

0.6

0.7

042

High

Dry

1760

1700

1625

1535

1450

1350

1225

(Without Heater)

Wet

1690

1625

1545

1455

1355

1260

Medium

Dry

1615

1545

1490

1415

1345

1255

1150

Wet

1545

1495

1435

1365

1275

1185

Low

Dry

1435

1385

1340

1280

1210

1135

1035

Wet

1395

1350

1300

1235

1165

1080

042

High

Dry

1700

1635

1560

1475

1395

1290

(With Heater)

Wet

1625

1565

1485

1415

1320

1200

Medium

Dry

1565

1505

1450

1385

1305

1215

Wet

1510

1450

1390

1320

1235

1150

Low

Dry

1410

1360

1315

1250

1180

1100

Wet

1370

1325

1270

1205

1135

048

High

Dry

2075

1995

1910

1830

1745

1655

1550

(Without Heater)

Wet

1950

1870

1795

1725

1645

1555

1455

Medium

Dry

1900

1830

1765

1700

1625

1545

1450

Wet

1810

1745

1685

1615

1540

1455

Low

Dry

1710

1665

1615

1565

1510

1450

1370

Wet

1660

1615

1565

1515

1450

1385

048

High

Dry

1970

1905

1825

1755

1675

1580

1490

(With Heater)

Wet

1875

1800

1740

1660

1580

1490

1400

Medium

Dry

1830

1770

1705

1635

1560

1485

Wet

1750

1690

1630

1560

1485

1400

Low

Dry

1670

1625

1580

1525

1470

1405

Wet

1620

1575

1525

1470

1390

_

060

High

Dry

2315

2280

2240

2200

2155

2115

2065

(Without Heater)

Wet

2250

2215

2165

2140

2095

2045

1990

Medium

Dry

2125

2080

2040

1995

1950

1905

1850

Wet

2065

2025

1990

1945

1900

1850

1790

Low

Dry

1900

1870

1840

1805

1770

1730

1690

Wet

1860

1830

1800

1760

1730

1680

1650

060

High

Dry

2265

2230

2190

2145

2100

2060

2010

(With Heater)

Wet

2210

2170

2130

2085

2045

2000

1950

Medium

Dry

2070

2035

1995

1955

1915

1870

1820

Wet

2025

1985

1945

1910

1865

1820

1765

Low

Dry

1875

1850

1820

1785

1750

1710

1665

Wet

1850

1815

1780

1750

1715

1675

1625

OPTIONAL FIELD-INSTALLED ELECTRIC HEAT PACKAGES*

Heater

P/N

517E

Sizes
Used

Witht

Heater

Volts-

Phase

(60 Hz)t

Nominal Heater KW

@ 240V**

Heater

Capacity

(MBtuh)**

Internal

Circuit

Protection

Provided

Supply

Circuit

Options

Approx

Ship.

Wt

(lbs)

Total

KW/Stage

1st

2nd

3rd

208V

230V

305971-451

042, 048, 060

208/230-1

7.5

7.5

19.2

23.5

None

Single

13

305971-452

042, 048, 060

208/230-1

10

10

25.6

31.3

None

Single

13

305971-453

042, 048, 060

208/230-1

10

10

25.6

31.3

Ckt Brkr

Single

14

305971-470

042, 048, 060

208/230-3

10

6.66

3.33

_

25.6

31.3

None

Single

14

305971-471

042, 048, 060

208/230-1

12

8

4

30.8

37.6

Fuses

Duaitt

15

305971-472

042, 048, 060

208/230-1

15

10

5

38.5

47.0

Fuses

Dualtt

15

305971-473

042, 048, 060

208/230-1

15

10

5

38.5

47.0

Ckt Brkr

Dual

15

305971-474

042, 048, 060

208/230-3

15

10

5

38.5

47.0

None

Single

15

305971-475

042, 048, 060

208/230-3

18

12

6

46.1

56.4

None

Single

15

305971-476

042, 048, 060

208/230-1

20

10

10

51.3

62.7

Fuses

Duaitt

17

305971-477

042, 048, 060

208/230-1

20

10

10

51.3

62.7

Ckt Brkr

Dual

17

305971-478tt

048, 060

208/230-3

25

8.33

8.33

8.33

64.1

78.4

Fuses

Single

20

305971-479tt

048, 060

208/230-3

30

10

10

10

76.9

86.0

Fuses

Single

20

♦Refer to the appropriate unit/factory-installed heater combinations in the specifications tabies in this PDS for the eiectrical appiication data for these

heat packages.

fAli heat packages are used with Modei 517G Fan Units.
^Operating voitage range is 187—253V.

**KW vaiues shown are nominai rated heater outputs at 240V. Capacity vaiues shown are caicuiated using nominai KW outputs.

ttThese heaters are fieid-convertibie for singie-phase operation by moving two factory high-voltage wires.
ttThese heaters are factory-supplied for dual-circuit operation. Optional single-circuit kit P/N 301820-4001 is available to provide for single-circuit

operation.

SSC-71