SPECIFICATIONS—UNITS WITH ELECTRIC HEATER

I

MODEL

517G

SIZE

H048020

P0480Z5H

P048030I

I N060075 I N060010 I P060010 I N060012

1 RATINGS & PERFORMANCE

Nominal Capacity (Btuh)*

48,000

48,000

48,000

60,000

60,000

60,000

60,000

Nominal Airflow (FF/Min)t

1600

1600

1600

2000

2000

2000

2000

Electric Heating Output (KW)t

20.0

25.0

30.0

7.5

10.0

10.0

12.0

Electric Heating Capacity (MBtuh)f:

51.3/62.7

64.1/78.4

76.9/86.0

19.2/23.5

25.6/31.3

25.6/31.3

30.8/37.6

1 ELECTRICAL ^

Unit Volts-Phase (60 Hz)

208/230-1

208/230-3 1 208/230-1 ■

208/230-3 1 208/230-1B

208/230-1

208/230-1

208/230-3

208/230-1

Operating Voltage Range

187-253

187-253

187-253

187-253

187-253

187-253

187-253

Internal Circuit Protection**

Fuses

CBtt

Fuses

Fuses

None

None

ICBtt

None

Fuses

Single-Circuit Operation

Rated Load Amps

76.8/84.8

_

56.8/62.5

94.8/104.8

67.2/74.1

112.8/124.8

32.6/35.6

41.6/45.6

26.4/28.6

49.0/53.6

Minimum Ampacity for Wire Sizing

97/107

-

72/79.1

119.5/132

85/93.6

142/157

40.8/44.5

52/57

33/35.75

61.25/67

Minimum Wire Size***

3/2

4/4

1/0

3/3

0/00

8/8

6/6

8/8

6/4

Maximum Wire Length (Ft)***

119/151

156/157

154/194

167/168

163/205

90/91

110/111

.136/139

93/149

Maximum Fuse Size (Amps)

100/110

80/80

125/150

90/100

150/175

45/45

60/60

35/40

70/70

Dual-Circuit Operation

Rated Load Amps L1 & L2

40.8/44.8

_

_

_

_

_

34.5/37.6

L3&L4

36/40

_

-

-

-

14.5/16

Minimum Ampacity for Wire Sizing

L1 & L2

52/57

_

_

_

_

_

43.1/47

L3&L4

45/50

-

_

-

18/20

Minimum Wire Size*** L1 & L2

6/6

-

-

-

-

.

8/6

L3&L4

8/6

-

_

-

-

-

12/12

Maximum Wire Length (Ft)*** Lt &L2

112/113

-

-

_

-

-

85/135

L3&L4

81/126

_

-

-

_

80/80

Maximum Fuse Size (Amps) L1 & L2

60/60

-

-

- ■

-

45/50

L3&L4

45/50

-

-

-

20/20

Control Transformer—24V (VA)

60

60

60

60

60

60

60

INDOOR COIL .

Rows & Fins Per Inch

3&.13

4 & 1 2

Height X Width (In.)

32.5 x22.8

32.5 x22.8

Face Area (Sq Ft)

5.1

5.1

R-22 Refrigerant Metering Device

Check-Flo-Rater

Check-Flo-Rater

Piston ID Number

82

88

Condensate Drain Connection (Pri-Sec)

3/4 MPT-3/4 FPT

3/4 MPT-3/4 FPT

INDOOR BLOWER & MOTOR

Wheel Diameter x Width (In.)

1 0 x 9

1 1 x 9

Filter Size—Cleanable (In.)

2 0 x 2 5 x 1

2 0 x 2 5 x 1

Blower Motor HP

1/2

3/4

Blower Motor Speeds & Type

3 & DD(PSC)

3 & DD(PSC)

Rated Load Amps

4.8

5.6

OPTIONAL EQUIPMENT (P/N’S)

I

Liquid-Tube Swivel Ell (3/8)tt

P651-1066

P651-1066

Vapor-Tube Swivel Ell (3/4)t1:

P651-1068

P651-1068

Single-Circuit Kit**

301802-4001 1 1 =

T 1 1 = |301820-4001

*See condensing unit or heat pump section PDS for cooling and/or heating capacity ratings with 517G Fan Coils.
tSee air delivery table in this PDS.
$KW values shown are nominal rated heater outputs at 240V and do not include blower motor heat. Capacity values shown are calculated using KW

outputs at 208V/230V.

**Single-phase 10-, 15-, or 20-KW electric heaters have the internal circuit protection options shown. Single-phase 12-, 15-, or 20-KW heaters are

wired for dual-circuit operation. The optional single-circuit kit may be field-installed in units with a 12-, 15-, or 20-KW single-phase fused heater for
single-circuit operation.

ttCB = circuit breakers.
ttUsed for right-angle refrigerant connections to the coil.

***Wire sizes and lengths are based on copper conductor at 86 ° F (30 ° C) ambient temperature and ampacity shown in table. Insulation must be 90 ° C

on conductor used between the disconnect switch and thé heater and at least 75 °C on the conductor used between the disconnect and the serv­
ice panel. If other than copper conductor is used, or if ambient temperature is above 86 ° F, determine wire size for ampacity shown and the National

Electric Code. Wire lengths shown are measured one way along the wire path between the disconnect and service panel for minimum 2%

voltage drop.

■Units with 25- and 30-KW electric heaters are wired for 3-phase operation. These units are field-convertible for single-phase operation by moving

two factory high-voltage wires.