Dimensions (inches), Weight distribution, Table i-585b ratings & recommended filter sizes – Bryant 585B User Manual

Page 2: C. clearances

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

DIMENSIONS (Inches)

Size

A

B

D

E

F

G

H

J

018050 & 024050

44-5/8

30-3/8

16

10

1-1/8

16

7-1/4

024075, 030075,

& 036075

44-5/8

40-3/8

19

10

_

1-3/8

13-1/4

8-7/8

036125, 042100,

& 048125

58-5/8

44-5/8

24

14

_

1-3/8

13-1/4

8-7/8

060125 & 060150

66-7/8

44-5/8

32

10

15-3/4

1-3/8

13-1/4

8-7/8

tLECTRlCAL DibCÜNNrCT
MAY BE MOUNTED ÜN
THIS PANEL

H------------------D------------------

_ 7

8

-Ft-

SUPPLY

AIR

RETURN

AIR

1

1

^ REAR VIEW

3L0W£R

ACCESS

ÜUOR

CONTROLS

ACCESS

DOOR

i!T

CONDENSER FAN

.1

?

.

TOP VIEW

A -

air

A

out

LEFT-SIDE VIEW

-IIGH-VOLTAGE

'

INLET

GAS

inlet

FRONT VIEW

WEIGHT DISTRIBUTION

A76216

Size

Shipping

Wt (Ibs)

Operating

Wt (Ibs)

Corner Wt (Ibs)

A

B

C

D

018050

325

300

77

75

73

75

024050

330

305

86

83

66

70

024075

425

395

115

110

83

87

030075

430

400

116

111

84

89

036075

440

405

117

112

85

91

036125

510

465

132

126

101

106

042100

520

475

136

129

103

107

048125

535

490

150

143

96

101

060125

600

550

142

136

132

140

060150

615

565

144

138

137

146

B

Figure 2—Model 585B Dimensional Drawing,

Shipping Weights, Operating Weights, & Weight Distribution

TABLE I-585B RATINGS & RECOMMENDED FILTER SIZES

SIZE

018050

024050

024075

030075

036075

036125

042100

048125

060125

060150

Rated Cooling Capacity (Btuh)*

18,500

23,000

24,000

29,000

37,000

35,500

42,000

47,000

59,000

59,000

Rated Cooling Airflow (Ft^/Min)*

690

850

900

1000

1200

1300

1550

1600

2200

2200

Rated,Maximum External Static Pressure

Single-Phase Units (In. wc)

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Three-Phase Units (In. wc)

0.65

0.65

0.65

0.65

0.65

0.65

ARI Sound Rating Numbert

19

20

19

19

20

20

20

20

21

21

Rated Minimum Heating Input (Btuh)t

40,000

40,000

60,000

60,000

60,000

100,000

80,000

100,000

100,000

120,000

Bonnet Capacity (Btuh)

30,000

30,000

45,000

45,000

45,000

75.000

60,000

75,000

75,000

90,000

Rated Maximum Heating Input (Btuh)t

50,000

50,000

75,000

75,000

75,000

125,000

100,000

125,000

125,000

150,000

Bonnet Capacity (Btuh)

37,500

37,500

56,250

56,250

56,250

93,750

75,000

93,750

93,750

112,500

Recommended Field-Supplied Filter Size

Standard-Type (Sq In.)

288

384

384/433**

480

576

576/722**

672

768

960

960

Cleanable- or High-Capacity-Type (Sq In.)

187

250

250/281**

312

374

374/469**

437

499

624

624

*Rated in accordance with ARI Standard 210-75.
t Rated in accordance with ARI Standard 270-75.
+AII units have two A.G.A.-certified heating input ratings and are manufactured with burner orifices that permit heating operation at the minimum rating. Units

may not be derated below this minimum rating. Optional field-installed burner orifices are required to provide the optional maximum heating input rating. See
Table V.

**When size 024075 or 036125 is installed to operate at the minimum rated heating input, the recommended filter area is the smaller square inch figure shown for

each type of filter. The larger square inch figures shown are recommended when these units have been field-converted to operate at the maximum rated heating
input. All other recommended filter sizes shown in the table are determined by the cooling airflow requirements only and are not affected by the heating operation
input rating.

4 inches thick and extends 6 inches beyond the casing on all

4 sides. The slab, should be a minimum of 3 inches above

finished grade and constructed so that water runoff will not

accumulate around unit. Be sure to locate the unit where

water can not drain directly on the unit.

C. Clearances

The minimum clearance is 6 inches from the duct side, 24 in­

ches from the condenser coil side, and 30 inches from the re­

maining two sides of the unit to allow for adequate service

space. Minimum clearance from the top of the vent is 24 in­

ches.

CAUTION:

The 24-inch side clearance stipulation assures

unrestricted airflow to the condenser fan inlet. Any restric­

tion at the inlet grille can be detrimental to compressor life.

The condenser fan discharge is through the top of the unit.

When installing the unit on the ground, do not locate in a

corner or under a complete roof cover such as a carport. Min­

imum clearance under a normal house roof construction is

-2-