Table 2. FS781/82/84 Recommended Loop Filter Values C7 (pF) @ +3.3 VDC ±5% (R6 = 3.3K)

[1, 2, 3, 4]

Input MHz

S1

S0

BW = 1.0%

[3]

BW = 1.5%

[3]

BW = 2.0%

[3]

BW = 2.5%

[3]

BW = 3.0%

[3]

BW = 3.5%

[3]

BW = 4.0%

[3]

6

0

0

10,000/1000

1550

910

780

700

640

560

8

0

0

10,000/330

990

820

640

520

450

400

10

0

0

1040

680

460

360

300

240

210

12

0

0

830

420

300

220

200

190

170

14

0

0

580

230

200

160

140

100

80

16

0

1

10000

980

760

580

470

410

385

18

0

1

1200

750

580

470

415

370

300

20

0

1

1000

730

470

390

320

220

190

22

0

1

960

640

410

270

230

200

180

24

0

1

920

400

250

210

180

160

150

26

0

1

660

300

220

180

150

140

120

28

0

1

470

230

180

150

130

100

70

30

0

1

470

180

140

120

100

80

60

32

0

1

330

170

120

100

82

68

47

34

1

0

10000

860

640

520

430

380

330

36

1

0

2200

820

620

470

400

330

290

38

1

0

1500

690

520

410

340

290

240

40

1

0

960

600

420

340

280

220

160

42

1

0

940

620

380

275

230

210

180

44

1

0

950

680

400

250

210

190

170

46

1

0

900

580

270

220

190

180

165

48

1

0

790

440

260

210

180

160

140

50

1

0

660

360

250

190

170

150

140

52

1

0

470

325

220

185

155

135

120

54

1

0

470

270

200

170

140

130

100

56

1

0

445

250

185

150

120

85

47

58

1

0

430

210

165

130

100

65

33

60

1

0

295

185

150

120

100

90

82

62

1

0

270

220

150

120

100

82

68

64

1

1

1180

860

560

410

340

290

230

65

1

1

1180

850

540

400

330

280

220

66

1

1

1180

760

560

350

260

220

210

68

1

1

1180

750

500

320

260

230

210

70

1

1

1120

740

470

370

300

240

170

72

1

1

1160

780

470

300

250

220

190

74

1

1

1110

770

470

280

230

210

190

76

1

1

1000

720

440

240

210

190

170

78

1

1

910

670

270

210

190

170

160

80

1

1

900

620

260

210

190

170

156

82

1

1

900

540

250

210

190

170

150

Notes:

1. If the value selected from the above chart is not a standard, use the next available larger value.
2. All bandwidths indicated above are total peak-to-peak spread. 1% = +0.5% to –0.5%. 4% = +2.0% to –2.0%.
3. If C8 is not listed in the chart for a particular bandwidth and frequency, it is not used in the loop filter.
4. Contact Cypress for LF values less than 1.0% bandwidth.