Cypress FS782 User Manual

Page 5

Advertising
background image

FS781/82/84

Document #: 38-07029 Rev. *F

Page 5 of 12

SSCG Modulation Profile

The digital control inputs S0 and S1 determine the modulation
frequency of FS781/2/4 products. The input frequency is
divided by a fixed number, depending on the operating range
that is selected. The modulation frequency of the FS78x can
be determined from Table 4. To compute the modulation
frequency, determine the values of S0 and S1, and find the
modulation divider number in Table 4.

Theory of Operation

The FS781/82/84 devices are phase-locked loop-(PLL)-type
clock generators using Direct Digital Synthesis (DDS). ‘By
precisely controlling the bandwidth of the output clock, the
FS781/2/4 products become a low-EMI clock generator. The
theory and detailed operation of these products will be
discussed in the following sections.

EMI

All clocks generate unwanted energy in their harmonics.
Conventional digital clocks are square waves with a duty cycle
that is very close to 50%. Because of the 50/50 duty cycle,
digital clocks generate most of their harmonic energy in the
odd harmonics (e.g., third, fifth, seventh). It is possible to
reduce the amount of energy contained in the fundamental
and harmonics by increasing the bandwidth of the funda-
mental clock frequency. Conventional digital clocks have a
very high Q factor, which means that all of the energy at that
frequency is concentrated in a very narrow bandwidth, conse-

quently, higher energy peaks. Regulatory agencies test
electronic equipment by the amount of peak energy radiated
from the equipment. By reducing the peak energy at the funda-
mental and harmonic frequencies, the equipment under test is
able to satisfy agency requirements for EMI. Conventional
methods of reducing EMI have been to use shielding, filtering,
multi-layer PCBs, etc. These FS781/2 and 4 reduce the peak
energy in the clock by increasing the clock bandwidth and
lowering the Q of the clock.

SSCG

The FS781/82/84 products use a unique method of modulating
the clock over a very narrow bandwidth and controlled rate of
change, both peak to peak and cycle to cycle. The FS78x
products take a narrow band digital reference clock in the
range of 6–82 MHz and produce a clock that sweeps between
a controlled start and stop frequency and precise rate of
change. To understand what happens to an SSCG clock,
consider that we have a 20-MHz clock with a 50% duty cycle.
From a 20-MHz clock we know the following:
Clock Frequency = Fc = 20 MHz.
Clock Period = Tc = 1/20 MHz = 50 ns.

Consider that this 20-MHz clock is applied to the X

IN

input of

the FS78x as either an externally driven clock or the result of
a parallel resonant crystal connected to pins 1 and 2 of the
FS78x. Also consider that the products are operating from a
5V DC power supply and the loop filter is set for a total
bandwidth spread of 2%. Refer to

Figure 2.

Table 4. Modulation Rate Divider Ratios

S1

S0

Input Frequency Range (MHz)

Modulation Divider Number

0

0

6 to 16

120

0

1

16 to 32

240

1

0

32 to 66

480

1

1

66 to 82

720

Xin

+ .5%

- .5%

TIME (microseconds)

1.0%
Total

Figure 1. Frequency Profile in Time Domain

[5]

Note:

5. With the correct loop filter connected to Pin 4, the following profile will provide the best EMI reduction. This profile can be seen on a Time Domain Analyzer.

[+] Feedback

Advertising
This manual is related to the following products: