Fs781 (soic) – Cypress FS782 User Manual

Page 7

Advertising
background image

FS781/82/84

Document #: 38-07029 Rev. *F

Page 7 of 12

**

** Occasionally, C8 is used to
create a second pole for this loop
filter. Refer to Loop Filter Selection
table.

Mount loop filter components as

close to LF pin as possible.

.

Crystal is 20 MHz is 1st Order

with 18 pF load capacitance.

If Crystal load capacitance is

different than 18 pF, C1 and C2

must be re-calculated.

For third overtone crystals, a

parallel or series resonant trap

is required.

R6

C1

0.1 uF

C2

27 pF

C3

27 pF

Y1

20 MHz

C8

C7

FS781
(SOIC)

Xin

1

Xout

2

S1

3

LF

4

VSS

5

FSOUT

6

S0

7

VDD

8

VDD

FSOUT

Figure 5. FS781 Schematic